Page 9 of 17

4.

O

PERATION

Control Panel

Operation

To access the control panel functions, use the four buttons located underneath the

display.

Button

Function

<MODE>

Press to find an operation mode or to back out of the current menu

option

<ENTER>

Press to activate a menu option or a selected value

<UP>

Press to scroll up the list of options or to find a higher value

<DOWN>

Press to scroll down the list of options or to find a lower value

Menu Map

Mode

Programming Steps

Description

ACt

Automatic

Operation

(extra levels not

available in all

programs)

A000-A023

F000-F100 Flash speed (slow to fast)

P000-P100 Run speed (slow to fast)

C000-C100 Color

SYS

SdAd

000-509

Set DMX address

SAAd

Reset software

Configuration

(DMX)

Set the product in DMX mode to control with a DMX controller.
1. Connect the product to a suitable power outlet.
2. Turn the product on.
3. Connect a DMX cable from the DMX output of the DMX controller to the DMX input

socket on the product.

Starting Address

When selecting a starting DMX address, always consider the number of DMX channels

the selected DMX mode uses. If you choose a starting address that is too high, you could

restrict the access to some of the product’s channels.
The COLORstrip™ uses up to 4 DMX channels in its 4-channel DMX mode, which

defines the highest configurable address to

509.

If you are not familiar with the DMX protocol, see the DMX Primer online at

www.chauvetlighting.com

To select the starting address, do the following:
1. Press

<MODE> repeatedly until SYS or ACt shows on the display.

2. Use

<UP> or <DOWN> to select SYS.

3. Press

<ENTER>.

4. Use

<UP> or <DOWN> to select SdAd from the menu.

5. Press

<ENTER>.

6. Use

<UP> or <DOWN> to select the starting address.

7. Press

<ENTER>.