To UNLOCK , Press MENU.
Touch and hold icon for 5 seconds for 2 bars (if not there already).
Then touch and hold the icon for another 5 seconds. Each 5 second touch and hold must be separate.
Return

HOME by touching the

icon.

CALIBRATE

Your thermostat was accurately calibrated at the factory to ±1° F of actual ambient

temperature. You do have the option, however, to change the display temperature to match that of a

previous thermostat, or to match another thermostat already in your home. The range of change is from

-6°F to +6°F or -3°C to +3°C.

To change your Thermostat Calibration, touch MENU and then touch CALIBRATE.

Use the + / - to adjust the displayed temperature up or down, as desired.

The DELTA FACTOR that appears on the screen will also automatically increase or decrease for

each 0.5° (F or C) adjustment so you can see your change. The large display will show the modified

temperature reading that will be displayed on the HOME screen and used as the new room temperature.

Press

HOME to return to the Home screen.

DIFF

(Used for 2 stage normal or heat pump with auxillary only, not on screen for single stage).

The differential is the number of degrees between the room temperature and the Target Temperature at

which the 2nd stage will be used. Default is 2°F.

Touch

MENU and then DIFF. use the arrows to set the DIFF.

Recommend

DIFF be set to 2°F for very cold climates and to 4°F for warm climates.