Manual screen functions – 3M 30 User Manual

Page 12

Advertising
background image

PG

12

PG

12

MANUAL Screen Functions

The 3M-30 has 4 manual override commands. The manual screen is accessed by touching the large

current temperature display on the middle of the HOME screen.

IMPORTANT: The Mode must be in HEAT or COOL to access the manual screen.

TEMPORARY override Touch the + / - arrows to select your desired temporary Target Temperature.

Touch HOME to return to operation. The

TEMPORARY icon will display indicating you have modified

the Target Temperature for the current Time Slot only. It goes back to the program target at the next

period. Also once in temporary, if the target is set the same as the programmed target for that period,

the word TEMPORARY will go out.

HOLD This will hold the target temperature you set indefinitely, until you turn HOLD off. HOLD will allow

you to operate your thermostat as a manual thermostat. It will keep whatever temperature you set until

you change it or cancel hold. Take care using the

HOLD function as the program is now bypassed. To set

a hold target temperature, touch

HOLD and use the +/- icons to select your hold temperature. The HOLD

icon will display on the HOME screen indicating you have changed the Target Temperature. The system

will

HOLD this temperature until you return to the manual screen and de-select HOLD by touching it. Hold

is also canceled when you set the mode to OFF.

HOLIDAY This is a single program that repeats day after day until you turn it off. It supersedes the

weekly program. To use it touch

HOLIDAY on the temporary screen. The default holiday program is

shown below. To modify this program, touch the PROGRAM button and then touch the DAY area until