Regulatory Compliance and Safety Information for Cisco 1800 Integrated Services Routers (Fixed)

OL-10256-02

Safety

Operating Conditions for Australia and the European Community

Operating Conditions for the United Kingdom

Warning

This equipment will be inoperable when mains power fails. Statement 198

Warning

High leakage current—permanent earth connection essential before making Telecommunication
Network Connection.
Statement 343

Warning

To avoid electric shock, do not connect safety extra-low voltage (SELV) circuits to telephone-network
voltage (TNV) circuits. LAN ports contain SELV circuits, and WAN ports contain TNV circuits. Some
LAN and WAN ports both use RJ-45 connectors. Use caution when connecting cables.
Statement 1021

Warning

Never touch uninsulated telephone wires or terminals unless the telephone line has been
disconnected at the network interface.
Statement 1037

Warning

Avoid using a telephone (other than a cordless type) during an electrical storm. There may be a remote
risk of electric shock from lightning.
Statement 1038

Warning

For connections outside the building where the equipment is installed, the following ports must be
connected through an approved network termination unit with integral circuit protection.
10/100/1000 Ethernet
Statement 1044

Warning

Voltages that present a shock hazard may exist on Power over Ethernet (PoE) circuits if
interconnections are made using uninsulated exposed metal contacts, conductors, or terminals.
Avoid using such interconnection methods, unless the exposed metal parts are located within a
restricted access location and users and service people who are authorized within the restricted
access location are made aware of the hazard. A restricted access area can be accessed only
through the use of a special tool, lock and key or other means of security.
Statement 1072

Warning

No user-serviceable parts inside. Do not open. Statement 1073

Agency Approvals and Standards

This section lists the following agency approvals and standards for safety:

CSA Certified to UL 60950 and CSA 22.2 No. 60950

ACA to AS/NZS 60950

CB Certificate/Test Report to IEC 60950-1, edition 1 (2001) with all country deviations, as well as
to EN 60950-1