Chamberlain ATS 2113X User Manual

Page 17

Advertising
background image

17

Hex Bolt
1/4-20 x 1-1/2"

"C" Wrap

Sensor
with Wire

Wing
Nut

Indicator
Light

Figure 6

Invisible Light Beam
Protection Area

Safety Reversing
Sensor

Safety Reversing
Sensor

Connect Wire to
Opener Terminals

Bell Wire

Bell Wire

Finished
Ceiling

Sensor
Connections

Wall Control
Connections
(dotted line)

OPENER TERMINAL SCREWS

1

2

3

Figure 7

MOUNTING AND WIRING THE SAFETY SENSORS

Center each sensor unit in a “C” wrap with lenses pointing

toward each other across the door (see Figure 6).

Secure sensors with the hardware shown. Finger tighten the

wing nut on the receiving eye to allow for final adjustment.
Securely tighten the sending eye wing nut.

Run the wires from both sensors to the opener (see Figure 7).

Use insulated staples to secure the wire to wall and ceiling.

Strip 1/4" (6 mm) of insulation from each set of wires. Separate

white and white/black wires sufficiently to connect to the
opener terminal screws: white to 2 and white/black to 3.

ALIGNING THE SAFETY SENSORS

Plug in the opener. The indicator lights in both the

sending

and receiving eyes will glow steadily if wiring connections and
alignment are correct.

The sending eye indicator light will glow regardless of alignment
or obstruction. If the indicator light in the receiving eye is off, dim,
or flickering (and the invisible light beam path is not obstructed),
alignment is required.

Loosen the

sending eye wing nut and readjust, aiming directly

at the receiving eye. Lock in place.

Loosen the

receiving eye wing nut and adjust sensor until it

receives the sender’s beam. When the green indicator light
glows steadily, tighten the wing nut.

TROUBLESHOOTING THE SAFETY SENSORS

If the

1.

sending eye indicator light does not glow steadily after

installation, check for:

Electric power to the opener.

A short in the white or white/black wires. These can occur at

staples, or at opener connections.

Incorrect wiring between sensors and opener.

A broken wire.

If the

2.

sending eye indicator light glows steadily but the

receiving eye indicator light doesn't:

Check alignment.

Check for an open wire to the

receiving eye.

If the

3.

receiving eye indicator light is dim, realign either sensor.

NOTE: When the invisible beam path is obstructed or misaligned
while the door is closing, the door will reverse. If the door is
already open, it will not close. The opener lights will blink 10
times. (If bulbs are not installed, 10 clicks can be heard.) See
page 15.