Troubleshooting, Please read the following carefully, Safety opera tion maintenance setup – Chicago Electric 10" Industrial Tile/Brick Saw 69275 User Manual

Page 16

Advertising
background image

Page 16

For technical questions, please call 1-800-444-3353.

Item 69275

SAFETY

OPERA

TION

MAINTENANCE

SETUP

Troubleshooting

Problem

Possible Causes

Likely Solutions

Tool will not start. 1. Cord not connected.

2. No power at outlet.

3. Tool’s thermal reset breaker tripped.

4. Internal damage or wear. (Carbon

brushes or switch, for example.)

1. Check that cord is plugged in.
2. Check power at outlet. If outlet is unpowered,

turn off tool and check circuit breaker.

If breaker is tripped, make sure circuit is right

capacity for tool and circuit has no other loads.

3. Turn off tool and allow to cool.

Press reset button on tool.

4. Have technician service tool.

Tool operates

slowly.

Extension cord too long or

wire size too small.

Eliminate use of extension cord.

If an extension cord is needed, use shorter/

heavier gauge cord. See Table A on page 3.

Performance

decreases

over time.

1. Blade dull or damaged.
2. Carbon brushes worn or damaged.

1. Keep cutting accessories sharp. Replace as needed.
2. Have qualified technician replace brushes.

Excessive noise

or rattling.

Internal damage or wear. (Carbon

brushes or bearings, for example.)

Have technician service tool.

Overheating.

1. Forcing machine to work too fast.
2. Blade misaligned.
3. Blade dull or damaged.
4. Blocked motor housing vents.

5. Motor being strained by long or

small diameter extension cord.

1. Allow machine to work at its own rate.
2. Check and correct Blade alignment to fence and table.
3. Keep cutting blades sharp. Replace as needed.
4. Wear ANSI-approved safety goggles and

NIOSH-approved dust mask/respirator while

blowing dust out of motor using compressed air.

5. Eliminate use of extension cord.

If an extension cord is needed, use shorter/

heavier gauge cord. See Table A on page 3.

Follow all safety precautions whenever diagnosing or servicing the tool.

Disconnect power supply before service.

PLEASE READ THE FOLLOWING CAREFULLY

THE MANUFACTURER AND/OR DISTRIBUTOR HAS PROVIDED THE PARTS LIST AND ASSEMBLY DIAGRAM

IN THIS MANUAL AS A REFERENCE TOOL ONLY. NEITHER THE MANUFACTURER OR DISTRIBUTOR

MAKES ANY REPRESENTATION OR WARRANTY OF ANY KIND TO THE BUYER THAT HE OR SHE IS

QUALIFIED TO MAKE ANY REPAIRS TO THE PRODUCT, OR THAT HE OR SHE IS QUALIFIED TO REPLACE

ANY PARTS OF THE PRODUCT. IN FACT, THE MANUFACTURER AND/OR DISTRIBUTOR EXPRESSLY

STATES THAT ALL REPAIRS AND PARTS REPLACEMENTS SHOULD BE UNDERTAKEN BY CERTIFIED AND

LICENSED TECHNICIANS, AND NOT BY THE BUYER. THE BUYER ASSUMES ALL RISK AND LIABILITY

ARISING OUT OF HIS OR HER REPAIRS TO THE ORIGINAL PRODUCT OR REPLACEMENT PARTS

THERETO, OR ARISING OUT OF HIS OR HER INSTALLATION OF REPLACEMENT PARTS THERETO.

Record Product’s Serial Number Here:
Note:
If product has no serial number, record month and year of purchase instead.

Note: Some parts are listed and shown for illustration purposes only,

and are not available individually as replacement parts.