SPECIFICATIONS

MODEL

544B018

SERIES DATA

A

PERFORMANCE DATA

ARI Noise Rating Number*

7.6 _ I

508A

024

_

_

510B

024

513C

018

024

__

516A

_

__

018

024

517E

— ■

__

018

024

519D/509A

_

—n—1

__

018

024

Rated Cooling Capacity -47“F

18700

18900

18000

18500

18700

18900

18600

19000

18200

18700

HSPF

6.85

6.95

6.70

6.90

6.85

6.85

6.65

6.85

6.65

6.90

Rated Cooling Capacity Btuhf

17700

17300

17000

17600

17600

17800

16700

17200

17000

17700

SEER

9.50

9.35

9.35

9.45

9.30

9.50

9.00

9.15

9.25

9.50

SEER w/TDR

10.00

9.85

9.90

9.95

9.80

10.00

9.45

9.65

9.75

10.00

MODEL

544B024

SERIES DATA

A

PERFORMANCE DATA ' •

ARI Noise Rating Number*

1_____________________ 7.6 1

506 B

030

036

__

513C

_

024

030

517E

024

030

036 ’

------------------ 1

509A/519D

024

030

030X

508A

024

Rated Cooling Capacity -47°F

25000

25600

24800

25400

25400

25400

25400

25000

25200 1

25200

25200

HSPF

1 6.70

6.95

6.60

6.75

6.70

6.70

6.75

6.80

6.85

6.85

6.60

Rated Cooling Capacity Btuht

22400

22800

22000

22800

21400

22800

23000

22800

23000

23000

22800

SEER

9.60

9.60

9.30

9.50

9.00

9.50

9.50

9.50

9.65

9.65

9.50

SEER w/TDR

10.00

1 10.30

9.70

1 9.90

9.40

9.90

9.90

9.90

10.10

10.10

9.90

MODEL

544B030

SERIES DATA

A

PERFORMANCE DATA

ARI Noise Rating Number*

1_________________________ . 7.6 1

505B

030

036

042

_

~

519D

-

030

036X

-

-

_

510B

030

036

508A

__ j

~ i

035

1

513C

-

-

-

030

-

-

-

517E

-

030

036

042

519C

-

-

-

-

- ,

_

1

-

042

-

519G with 520B042

1 —

_ 1

1

_

. —

-----------------1

_

042

— ■ ■

509Aor519D

~

-

-

-

-

-

_

030X

036

Rated Cooling Capacity - 47°Ft

30,600

31,800

31,800

31,200

31,400

31,200

31,600

30,600

31,600

31,200

31,600

32,200

31,800

31,800

31,200

31,400

HSPF

6.90

7.15

7.15

7.00

7.10

6.90

7.05

7.15

6.95

6.85

7.05

7.20

7.20

7.20

7.00

7.10

Rated Cooling Capacity Btuht

27,600

28,600

28,600

28,000

28,400

27,800

28,600

28,400

28,200

27,600

28,600

29,200

29,400

29,400

28,000

28,400

SEER

9.10

9.25

9.25

9.30

9.40

9.20

9.35

9.30

9.00

9.00

9.20

9.35

9.35

9.25

9.30

9.40

SEER w/TDR

9.50

9.70

9.60

9.70

9.80

9.60

9.75

9.50

9.40

9.25

9.60

9.80

9.75

9.70

9.70

9.80

MODEL

544B036

SERIES DATA

PERFORMANCE DATA

ARI Noise Rating Number*

7.6

506B

036

042

048

508A

036

510B

036

048

517E

036

042

043

048

_

— ■

519C

042

519C-F520B042

-

042

519D/509A

036

042

042X

042C

043

043X

_

519D

036X

Rated Cooling Capacity -47°Ft

37600 37600 38000 36800 37400 38500 37600 38000 38000 38500 38000 38000 37200 37800 37800 37200 37400 37400 37200

HSPF

6.85

6.85

6.95

6.70

6.85

7.10

6.70

7.00

7.00

7.10

6.90

6.90

6,90

7.00

7.00

7.05

7.10

7.10

6.90

Rated Cooling Capaoity Btuht

35000 35000 35400 33800 34600 36400 34400 35800 35800 36200 35600 35600 34600 35400 35400 35400 35500 35600 34600

SEER

9.55

9.55

9.65

9.30

9.55

9.80

9.25

9.65

9.45

9.75

9.65

9.60

9.55

9.75

9.75

9.75

9.80

9.80

9.55

SEER w/TDR

10.00

10.00

10.15

9.50

10.00

10.25

9.65

10.05

9.80

10.25

10.15

10.00

10.20

10,20

10.20

10.25 10.25

10.00

EER30

8.95

8.95

9.05

8.80

8.95

9,15

8,65

9.00

9.10

9,10

9.00

9.00

8,90

9.00

9.00

9.00

9.10

9.10

8,90

*lf other than 60°C copper wire is used, size can be determined from unit ampacity given in above tabie and applicabie tabie of National Electric

Code. Wire size selected must have current capacity not less than that of copper wire specified and must not create a voltage drop between service
panel and unit in excess of 2% of unit rated voltage.

tThe factory refrigerant charge is sufficient for systems requiring up to 30-feet of interconnecting tubing. For tubing lengths other than 30-feet, see

Installation Instructions for additional refrigerant requirements.

TSingle-phase units may use fuses or HACR-type circuit breakers (U.S. only) of same size as noted.