DETAILED COOLING CAPACITIES*

Air

85

95

105

115

E

Capacity

Total

Capacity

Total

Capacity

Total

• Capacity

Total

CFM

W

MBtuht

System

MBtuht

System

MBtuht

System

MBtuht

System

B

Total

Senst

KW* **

Total

Sensi

KW**

Total

Sensi

KW**

Total

Sensi

KW**

544B042 Outdoor Section With 517E/GN048 Indoor Section

72

47.1

23.4

4.60

44.5

22.4

4.92

42.0

21.5

5.24

39.2

20.5

5.54

1400

67

42.8

29.9

4.46

40.4

28.9

4.76

38.0

27.9

5.06

35.5

26.9

5.34

62

38.9

36.0

4.33

36.8

34.9

4.62

34.6

33.7

4.90

32.5

32.3

5.17

57

37.8

37.8

4.29

36.1

36.1

4.59

34.3

34.3

4.88

32.4

32.4

5.17

72

47.8

24.3

4.71

45.0

23.3

5.03

42.4

22.4

5.36

39.4

21.3

5.66

1575

67

43.5

31.5

4.58

41.0

30.5

4.88

38.4

29.5

5.18

35.7

28.4

5.46

62

39.7

38.1

4.45

37.5

36.8

4.74

35.4

35.3

5.03

33.4

33.4

5.32

57

39.1

39.1

4.43

37.2

37.2

4.73

35.3

35.3

5.03

33.4

33.4

5.32

72

48.3

25.1

4.82

45.4

24.1

5.14

42.7

23.2

5.46

39.7

22.2

5.77

1750

67

43.9

33.0

4.68

41.3

32.0

4.99

38.7

30.9

5.28

36.1

29.9

5.57

62

40.5

39.9

4.57

38.3

38.3

4.87

36.3

36.3

5.17

34.2

34.2

5.46

57

40.2

40.2

4.56

38.3

38.3

4.86

36.3

36.3

5.17

34.2

34.2

5.47

CONDENSER ENTERING AIR TEMPERATURES °F

Multipliers for Determining the Performance With Other Indoor Sections

Indoor

Section

Size

Cooling

Capacity

Power

Indoor

Section

Size

Cooling

Capacity

Power

506B

508A

042

0.98

0.96

519C

042

1.00

0.98

048

0.99

0.97

060

1.04

0.99

049

1.00

0.97

519C &

520B042

042

0.98

0.99

048

1.01

0.96

060

1.02

1.02

510B

517E/G

048

1.01

0.98

519D/509A

042

0.99

0.95

060

1.04

0.99

042X

0.99

0.95

042

0.99

1.00

042C

0.99

0.97

043

1.00

0.97

043

1.02

0.97

048

1.00

1.00

043X

1.02

0.97

049

1.01

0.98

048X

1.02

0.97

060

1.01

1.04

519D

048

1.02

0.97

062

1.01

1.03

048C

1.02

0.97

049

1.04

0.97

544B048 Outdoor Section With 517E/GN060 Indoor Section

1600

72
67
62
57

51.6
47.2
43.2
42.6

26.2
34.0
41.2
42.6

5.27
5.12
4.97
4.95

48.8
44.4
40.9

40.5

25.2
32.9
40.0

40.5

5.64
5.45
5.30

5.28

45.8
41.5
38.5

38.3

24.1
31.8

38.4
38.3

5.98
5.78
5.61
5.61

42.7
38.7
36.2
36.2

23.1
30.6
36.2
36.2

6.32
6.09
5.93
5.93

72

52.3

27.3

5.41

49.2

26.2

5.77

46.1

25.2

6.12

42.9

24.1

6.46

1800

67

47.8

36.0

5.25

45.0

34.9

5.59

42.1

33.7

5.92

39.1

32.5

6.23

62

44.1

43.5

5.12

41.9

41.8

5.45

39.6

39.6

5.79

37.2

37.2

6.11

57

43.9

43.9

5.11

41.7

41.7

5.45

39.4

39.4

5.78

37.3

37.3

6.12

72

52.8

28.4

5.54

49.5

27.2

5.89

46.3

26.2

6.24

43.0

25.1

6.59

2000

67

48.2

37.8

5.37

45.3

36.6

5.71

42.3

35.4

6.04

39.3

34.2

■6.36

62

45.0

45.0

5.26

42.7

42.7

5.61

40.3

40.3

5.95

38.1

38.1

6.28

57

45.0

45.0

5.26

42.7

42.7

5.61

40.3

40.3

5.95

37.9

37.9

6.28

Multipliers for Determining the Performance With Other Indoor Sections

Indoor

Section

Size

Cooling

Capacity

Power

Indoor

Section

Size

Cooling

Capacity

Power

506B

048

0.96

0.96

519C

048

0.94

0.95

049

0.97

0.95

060

0.99

0.97

060

0.97

0.96

519C&

520B048

048

0.94

0.97

061

0.98

0.97

060

0.99

0.99

508A
510B

517E/G

048

0.98

0.94

519D/509A

048X

0.99

0.96

048

0.98

0.97

057C

1.02

0.95

060

1.02

0.98

060

1.02

0.97

048

0.96

0.98

061

1.07

0.96

049

0.99

0.96

519D

048

0.99

0.96

060

1.00

1.00

048C

0.99

0.95

062

1.01

1.00

049

1.02

0.95

063

1.02

1.01

*Detailed cooling capacities are based on indoor and outdoor unit at the same elevation and connected by 25 feet of tubing. If other than 25

feet of tubing is used and/or indoor unit is located above outdoor unit, a slight variation in capacity may occur.

fTotal and sensible capacities are net capacities. Blower motor heat has been subtracted.
^Sensible capacities shown are based on 80°F entering air at the indoor coil. For sensible capacities at other than 80°F, deduct 835 Btuh per

1000 Cfm of indoor coil air for each degree below 80°F, or add 835 Btuh per 1000 Cfm of indoor coil air per degree above 80°F.

**Unit KW is total of indoor and outdoor unit KW’s.