Maintenance
The ammeter shows you the rate
at which your batteries are charg
ing. Maximum charging rate
is approximately 7 to 8 amps. The
charging rate will drop to 3 amps
during the latter part of charging.
Figure 16
Charging Hints
1
Be sure the outlet used to
charge the battery is live and
does not shut off when you turn
off the lights.
2
Only use the charger built into
the mower to charge the bat
teries. Do not use any other
charger.
3
Do not use the battery in the
mower to “jump" any other
vehicle.
Battery Maintenance
Follow the instructions in the above
paragraph covering the charging
of the batteries. To charge a set
of batteries to 100% of capacity
will take a maximum of 12 hours.
Reading your ammeter during the
charging will give you an indication
of the state of charge of your bat
teries. If the ammeter reading is
over 6 Amps, you have less than
80% of capacity.
A hydrometer can be used to
check the state of charge of the
batteries. Always read a hydrometer
at eye level to obtain a true reading.
Keep the float vertical. A hy
drometer is designed to give the
correct reading at 80°F. This is
the electrolyte temperatuer, not the
air temperature. Draw enough elec
trolyte into the hydrometer so the
float does not touch the bottom of
the tube. A correction chart is
necessary to obtain a true reading.
(See figure 17.)
Temperature Correction Chart
°F.
Correction
120
-F.016
115
+ .014
110
+ .012
105
+ .010
100
+ .008
95
+ .006
90
+.004
85
1 +.002
80
0
75
-.002
70
-.004
65
-.006
60
-.008
55
-.010
50
-.012
45
-.014
40
-.016
35
. -.018
30
-.020
25
-.022
20
■ -.024
15
-.026
10
-.028
Figure 18
1.260 SpGr 1.280 SpGr 100% Chg
1.230 SpGr 1.250 SpGr 75% Chg
1.200 SpGr 1.220 SpGr 50% Chg
1.170 SpGr 1.190 SpGr 25% Chg
1.140 SpGr 1.160 SpGr Very little
useful capacity
1.110 SpGr 1.130 SpGr Discharged
Figure 19
Examples of Reading
Specific Gravity
Hydro. Read. (fig. 17)
1.230 SpGr
Electrolyte Temp.
30° F.
Temp, Correction (fig. 18)
-.020
Corrected SpGr*
1.210 SpGr
17)
Hydro. Read, (fig
Electrolye Temp.
Temp. Correction (fig
Corrected SpGr*
1.230 SpGr
100° F.
18)
-F.008
1.238 SpGr
Figure 17
*Compare to figure 19.