Fuses

Loudspeaker fuses

These are 1.6 Amp (or less) fast blow 20mm x 5mm diameter fuses. They may blow if the

amplifier is:

- run continuously at high level into the correct loudspeaker load

- run at high level into a loudspeaker of too low an impedance (“4ohms” or less)

- run into a short circuit

They are user-replaceable and two spares are provided. However, if they blow consistently

without any of the above conditions obtaining please consult your dealer. DO NOT replace with

a fuse of greater value than 1.6 Amps (or wth a “slow blow” or “anti-surge” fuse) since this will

endanger the amplifier and your loudspeakers and invalidate your guarantee.

Power supply fuses

These are 3.15 Amp fast blow 20mm x 5mm diameter fuses. They are NOT USER-

REPLACEABLE and spares are not supplied. If these fuses blow, there is probably a fault in

the amplifier - do not change the fuses but consult your dealer.

Mains fuse

This is a 1 Amp anti-surge (slow blow) 20mm x 5mm diameter in all models. This fuse is

designed to protect against faults in the amplMer, transformer and mains switch. It is not

normally user-replaceable. However, should it blow during a continuous period of very high level

music, or on amplifier switch-on, it may be replaced once only WITH A FUSE OF THE

CORRECT TYPE (one spare is provided). If a second fuse blows within a short period then

there is a fault, and the amplifier should be returned to your dealer.

Location of MC60

moving coil cartridge

pre-amplifier

(optional)

Location of disc

input loading

module (optional)

D.C. supply fuses

NOT USER

REPLACEABLE

Loudspeaker fuses

1.6 Amp quick blow

DO NOT replace with

higher values or anti-surge

types

I----1 I I I Í I _______________ ______ ______ ______

Mains fuse

1 Amp anti-surge

Removal of wooden cover

In order to inspect or change fuses, or adjust the tape replay level controls, you will need to

remove the wooden cover from the amplifier.
BEFORE REMOVING THE COVER, ALWAYS SWITCH OFF THE AMPLIFIER AND

DISCONNECT FROM THE MAINS SUPPLY.
Note that the mains fuse remains live whenever the amplifier is plugged into the mains, even

when the amplifier power switch is in the off position. To remove the cover unscrew the two

black-headed screws towards the rear of the side panels using a No.l “Pozidriv” screwdriver.

Tlien slide the cover forward as far as it will go (approximately 15mm) and lift it vertically

upwards. Replacement is merely a reversal of this procedure.