LIGHTING

INSTRUCTIONS

1. STOP! Read the safety information, page 14.

2. Make sure equipment shutoff valve is fully

open.

3. Turn off any electric power to the appliance

if service is to be performed.

4. Turn control knob clockwise

to the

OFF position.

5. Wait five minutes to clear out any gas. Then

smell for gas, including near the floor. If you

smell gas, STOP! Follow “B” in the safety

information, page 14. If you donʼt smell gas,

go to the next step.

6. Turn control knob counterclockwise

to the PILOT position. Press in control

knob for five (5) seconds.

7. With control knob pressed in, push down and

release ignitor button. This will light pilot.

The pilot is attached to the front of burner.

Note:

You may be running this heater for the

first time after hooking up to gas supply. If so,

you may need to press in control knob for 30

seconds or more. This will allow air to bleed

from the gas system. If needed, keep pressing

ignitor button until pilot lights. If ignitor does

not light pilot, refer to Troubleshooting, page

18 or contact a qualified service person or gas

supplier for repairs. Until repairs are made,

light pilot with match. To light pilot with match,

see Manual Lighting Procedure, page 16.

8. Keep control knob pressed in for 30 seconds

after lighting pilot. After 30 seconds, release

control knob.

• If control knob does not pop up when re-

leased, contact a qualified service person

or gas supplier for repairs.

Note:

If pilot goes out, repeat steps 4 thru 7.

Thermostat models have a safety interlock

system. Wait one (1) minute before lighting

pilot again.

9. Turn control knob counterclockwise

to desired heating level. The main burner

should light.

WARNING: Always operate

manual control heaters at the

locked positions. Operation

between these positions may

create a possible health hazard

if used in a poorly ventilated

room. Read owner’s manual for

complete instructions.

OF

F

P

ILO

T

Figure 21 - Control Knob In The OFF

Position

Piezo Ignitor

Figure 23 - Pilot (actual pilot may vary)

OPERATING HEATER

Continued

Ignitor Electrode

Pilot Burner

Thermocouple

TO TURN OFF GAS

TO APPLIANCE

Shutting Off Heater

1. Turn control knob clockwise

to the

OFF position.

2. Turn off all electric power to the appliance

if service is to be performed.

Shutting Off Burner Only (pilot stays lit)

Turn control knob clockwise

to the

PILOT position.

THERMOSTAT CONTROL

OPERATION

The thermostatic control used on these models

differs from standard thermostats. Standard

thermostats simply turn on and off the burner.

The thermostat used on this heater senses the

room temperature. The thermostat adjusts the

amount of gas flow to the burner. This increases

or decreases the burner flame height. At times

the room may exceed the set temperature. If so,

the burner will shut off. The burner will cycle

back on when room temperature drops below the

set temperature. The control knob can be set to

any heat level between 1 and 5. Selecting the 5

setting will cause the burner to remain fully on

without modulating down in most cases.

OFF

OF

F

PIL

OT

Electronic Ignitor

Figure 22 - Ignitor Buttons

CAUTION: Do not try to ad-

just heating levels by using the

equipment shutoff valve.