Troubleshooting

Problem

Cause

Action

Unit will not turn on

(no power LED indicator)

+12V wire not connected or incorrect voltage
REM wire not connected or incorrect voltage

Check connections for proper voltage
(11~16VDC)

GND wire not connected

Check connection to ground

Fuse(s) blown

Replace fuse(s)

Unit has power - LED is

green (but no sound)

Speaker wires not connected

Check connections at speakers

Volume turned all the way down

Increase volume level at head unit

One or more speaker wires touching each
other or touching chassis ground

Insulate all bare speaker wires from
each other and chassis ground

Speaker(s) defective or damaged

Check/replace speaker(s)

Input signal not connected

Check high or low level inputs for
proper connection

Unit blows fuse(s)

Incorrect fuse rating

Use fuse(s) with correct rating

+12V wire touching chassis ground

Check for pinched wire

Speaker(s) defective or damaged

Check/replace speaker(s)

Engine noise

Bad ground connection

Make sure amplifier is grounded to
clean bare metal

Signal ground loop or RFI
(radio frequency interference)

Re-route RCA cables from existing
high current wiring

LED illuminates red

(protect mode)

One or more speaker wires touching each
other or touching chassis ground

Insulate all bare speaker wires from
each other and chassis ground

Speaker(s) defective or damaged internally
(shorted)

Check/replace speaker(s)

Speaker load less than 2 ohms (stereo)
Speaker load less than 4 ohms (bridged)

Adjust speaker load - amplifier will
not operate at less than 4 ohms when
bridged

Distorted audio output

Incorrect input signal type or input level too
high

Check connections and reduce/adjust
input level

Low audio output

Incorrect input signal type or input level
too low

Check connections and increase/
adjust input level

Weak bass

Speaker(s) are wired out of phase

Check (+) and (-) speaker connections
(Observe correct polarity)

No illuminite output

(no lights)

Fuse blown - illuminite output (+12VDC) wire
touching ground

Check or replace fuse
Use 2 amp ATO fuse only

illuminite (+) or (-) wires not connected

Check connections at speakers

illuminite connections wired wrong
(reverse polarity)

Reverse (+) and (-) connections
(Observe correct polarity)

illuminite speaker(s) defective or damaged

Check/replace speaker(s)