ROOM STATION IBG-2AD & IBG-2CD OPERATION

(1) Receiving a call from

door station;

(2) Transferring a call from

door to another room:

room station;

A call is annunciated by chime and LED at all room sta­

tions. Pick up handset at convenient station and depress
the selector button at the left of the lighted LED (LED
remains lit for about 15 seconds).

Depress the room call button, which shuts off
talk path of door station. The transferred
room station can communicate with door
after depressing the corresponding selector
button. When the called station is not available,

depress the selector button to resume conver­
sation with door station.

(3) Operating door release; EL-9S door lock, if included, may be released

while depressing and holding the door release

button on room station.

(4) Placing a call to another Pick up handset and depress the call button. If your chime

intercom includes three room stations (one IBG-2AD and

two IBG-2CD), a call from one station will be annunciated
at both remaining stations. It is recommended to determine
in advance the call signal for each individual room. For
example,

■ M H B to call room #

(2),

wm

■ HI to call room # (a).

NOTE: (1) If door station calls during conversation

between room stations, chime will sound
only at the room station not occupied and
(if installed at IBR-1 extension device. The
two occupied stations will hear the incoming
call thru handset.

When a communication is heard upon your
picking up handset, do not depress room
call button, which will cut off the com­
munication with door station.

DOOR STATION CALLING OPERATION

Momentarily depress the call button. Talk and listen hands free to room station. Conversation will not be interrupted

even if you push the call button.

TO PREVENT ELECTRIC SHOCK:

* DO NOT CONNECT ANY TERMINAL ON ANY UNIT TO AC POWER LINES.
* When you mount IBG-2AD in place of existing bell or chimes, be sure to disconnect wires from present transformer.
* BE SURE TO REMOVE PLUG OF POWER SUPPLY FROM POWER OUTLET BEFORE YOU OPEN THE UNIT,

OR MAKE WIRING CONNECTIONS.

* Do not pinch connecting wires in windows, doors or desks.
* IBG-2AD equipment must be installed in as dry and dust-free environment as possible.

CLEANING YOUR INTERCOM STATIONS:

Your Aiphone intercom stations may be cleaned with a soft cloth dampened with household cleanser, such Mr. Clean or

Fantastik.

■a

-S

WARRANTY

Aiphone warrants its products to be free from defects of material and workmanship under normal use and service for a period of one

year after delivery to the ultimate user and will repair free of charge or replace at no charge, should it become defective upon which

examination shall disclose to be defective and under warranty. Aiphone reserves unto itself the sole right to make the final decision

whether there is a defect in materials and/or workmanship, and whether or not the product is within the warranty.

This warranty shall not apply to any Aiphone product which has been subject to misuse, neglect, accident, or to use in violation of

instructions furnished, nor extended to units which have been repaired or altered outside of the factory.

This warranty does not cover batteries or damage caused by batteries used in connection with the product.

This warranty covers bench repairs only, and any repairs must be made at the shop or place designated in writing by Aiphone. Aiphone

will not be responsible for any costs incurred involving on site service calls.

Aiphone Co., Ltd., Nagoya, Japan
Aiphone Corporation, Bellevue, Washington

IBG-2ADI-1085® NA

ALL OVER THE WORLD

AIPHONE^

PRINTED IN JAPAN ©

Advertising
This manual is related to the following products: