Installation, Wiring, Installation location requirements – Aiphone MY-DA User Manual

Page 2: Installation height, Maintenance, Never

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

a

BEFORE YOU INSTALL AND OPERATE THE EQUIPMENT

— Prohibitions and precautions —

INSTALLATION

1. DO NOT CONNECT ANY TERMINAL TO AC POWER LINES.

When you mount MY-DA in place of existing bell or chime, be sure to disconnect

wires from the present transformer.

2. DO NOT OPEN THE MY-DA UNIT, WITHOUT FIRST REMOVING PLUG OF

POWER SUPPLY FROM AC OUTLET.

3. Do not drop or hit the MY-DA which may damage the CCD camera unit.

4. Avoid running the connecting wires through doors, windows or between furniture,

which may pinch and disconnect the wires.

5. Install with straight 2-conductor wire. Coaxial cable cannot be used.

WIRING

When surplus wire(s) exists in the cable between video door station and video monitor,

it is possible that the picture quality would be interfered with. In that case, we suggest

connecting a 120 ohm resistor at each end of surplus wire(s).

120 ohrU'

■120 ohm

Video
door station.

m-^

Video monitor

NEVER

I

INSTALLATION LOCATION REQUIREMENTS

• Select the MY-DA installation location, observing the following

conditions.

1. Avoid installing the MY-DA in a location that would be

exposed to;

* direct sunlight,

*temperature/humidity extremes,

* water,

*oil,

*dust,

*iron dust,

* inflammable and chemical products, etc,,

or

* where the strong light source is behind the person standing

at the doorstation. The face will appear dark on the room

station monitor. This situation can occur when buildings

create shadows on entry areas.

*As shown, it is recommended that the MY-DA be installed

at an entrance not exposed to direct sunlight and with 200

to 300 lux secured on the object.

INSTALLATION HEIGHT

Taking the adults’ average height into consideration, decide a

most suitable height of MY-DA doorstation.

It is suggested that the center of a camera lens be installed at an

adults’ average height minus 10 cm (4").

* MAINTENANCE

1. Clean your MY-DA unit with a soft cloth dampened with

neutral household cleanser. Never use lacquer, thinner or

benzine, etc.

2. Do not splash water directly on unit.

- 2 -

WEST

NORTH

ENTRANCE

MY-DA

V \ ' I / y r '

iO-

SOUTH

NORTH

WEST

yj MY-DA

ENTRANCE

EAST

y

SOUTH

*ln new installation:

Approx. 500 mm

(19-11/16")

Average adults'
height minus

100 mm (4")

-------------

500 mm (19-11/16")

■¿//A

500 mm

\ (19-11/16")

Approx. 760 mm (29-15/16")

*When a spacer is installed:

Approx.
530 mm
(20-7/8")

Average adults'
height minus

100 mm (4")

500 mm (19-11/16")

/////////////////////z

“f

500 mm
(19-11/16")

1

Approx. 720 mm (28-5/16")

NEVER