CAPACITY, INPUT AND OUTPUT

MODEL

NUMBER

BTU

INPUT

PER

HOUR

Gallons

or

Litres

TANK

SIZE

FIRST
HOUR

RATING

100°F

RISE

GPH

or

LPH

RECOVERY-GALLONS

PER HOUR AT °F

TEMPERATURE RISE

MAXIMUM
AMPERES

120 V, 60

Hz,1

40°F

100°F

140°F

22°C

56°C

78°C

BTP-139/A 140,000

U.S. Gallons 81

0

GPH

0

136

97

5

Litres

306.6

0.0

LPH

0.0

514.8

367.1

BTP-199/A 199,000

U.S. Gallons 81

0

GPH

0

193

138

5

Litres

306.6

0.0

LPH

0.0

730.4

521.7

BTP-270/A 270,000

U.S. Gallons 81

0

GPH

0

262

187

5

Litres

306.6

0.0

LPH

0.0

991

707.8

BTP-370/A 370,000

U.S. Gallons 81

0

GPH

0

359

256

5

Litres

306.6

0.0

LPH

0.0

1358

970

DIMENSIONS AND SHIPPING WEIGHTS

MODEL

NUMBER

Inches

or

CM

DIMENSIONS

SHIPPING WEIGHT

A

B

C

0

E

G

H

J

GAS STANDARD ASME

IN

OUT

BTP-139/A

Inches 74.75

65

26-3/4

6

21-3/8

27-3/4

38

85.-1/4

1/2

556 Lbs.

658 Lbs. 1-1/2 1-1/2

CM

189.9

165.1

67.9

15.2

54.3

70.5

96.5

216.5

1.3

252.7 Kg

299.1 Kg 3.8

3.8

BTP-199/A

Inches 74-3/4

65

26-3/4

6

21-3/8

27-3/4

38

85-1/4

1/2

545 Lbs.

635 Lbs. 1-1/2 1-1/2

CM

189.9

165.1

67.9

15.2

54.3

70.5

96.5

216.5

1.3

247.7 Kg

288.6 Kg 3.8

3.8

BTP-270/A Inches 74-3/4

65

26-3/4

6

21-3/8

27-3/4

38

85-1/4

3/4

547 Lbs.

632 Lbs. 1-1/2 1-1/2

CM

189.9

165.1

67.9

15.2

54.3

70.5

96.5

216.5

1.9

248.6 Kg

287.3 Kg 3.8

3.8

BTP-370/A Inches 74-3/4

65

26-3/4

6

21-3/8

27-3/4

38

85-1/4

3/4

547 Lbs.

632 Lbs. 1-1/2 1-1/2

CM

189.9

165.1

67.9

15.2

54.3

70.5

96.5

216.5

1.9

248.6 Kg

287.3 Kg 3.8

3.8

’Natural & Propane (LP)

SUGGESTED SPECIFICATION

(Natural or Propane) gas water heater(s) shall be A. O. Smith Conservationist® Model BTP____ with a storage capacity of________

gallons, an Input rating of_____BTUs per hour, a recovery capacity of_____ GPH at 100°F temperature rise and a maximum

hydrostatic working pressure of 160 PSI. Heater(s) shall meet ASHRAE/IESNA 90.1 -1999 for thermal efficiency and standby loss.

Water heater(s) shall have glass-lined tank, protected against elctrolytic corrosion by multiple factory-installed anode rods. Other

standard equipment shall Include: 1) Powered gas burner with redundant main gas valves, electronic Ignition, automatic pilot gas

valves, gas pressure regulator, and flame Inspection port: 2) Handhole cleanout: 3) High temperature limit control: 4) Dual thermostat

for accurate temperature control; 5) Factory-Installed T&P valve.

Controls shall Include a Fenwal OSI to provide direct spark Ignition and flame monitoring. A prepurge of 30 seconds minimum shall

be provided. A trial for Ignition period of 5 seconds, after which If the flame Is not proved or lost during the running cycle, the system

will lock out.

Heater(s) tank shall have a 3-year (or extended 5- or 10-year limited) warranty against corrosion as outlined In the warranty.

A.O:Smith

Water Heaters

www.hotwater.com

500 Tennessee Waltz Parkway, Ashland City, TN 37015

For Technical Information and Automated Fax Service, call 800-527-1953.

A. 0. Smith reserves the right to make product changes or improvements without prior notice.

©2005 A.O. Smith Corporation

Printed in U.S.A.

ACGSS01305

Advertising
This manual is related to the following products: