System outline & components – Aiphone NEM-30/C User Manual
Page 2
Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".
1
SYSTEM OUTLINE & COMPONENTS
The NEM-n/C & NEM-nA/C are master stations of Lamp Memory Intercom for
10 to max. 40 sub stations. NEM master station is capable of carrying out
communication by either open voice press-to-talk or lifting handset operation,
as well as transmit aii call to all the sub stations simultaneously.
2 -tfAp Sub stations
<, NA-A,
etc.
P A CK A G E CO N TEN TS
Master station N EM -n/C,
N EM -nA /C
(n = 10, 20, 30 & 40)
Mounting hardware
Installation & Operation Manual
1 common + 1 Indiv. -
To sub zone (s) ^
irZ i-
1^]
24V DC power supply
PS-2410A
(in USA, 10 ~ 20-call)
PS-24ME
(in Europe, 10 ~ 20-caii)
PS-24E
(10 - 40-call)
A
To avoid noise interference, be sure to
take G terminal on PS-24E to earth.
Note: For more than 40 to max. 120-station system,
SOP (*) master stations are available;
NEM-50 ~ 120, NEM-50A ~ 120A (/7.A for CE).
C O M P O N EN TS A V A ILA B LE
Press-to-talk master station • Master station w/handset
' i
• 24V DC power supply
For up to 20 subs
P S-241 O A : 1A (120V AC)
P S-24M E: 0.9A (220V AC)
P S-24E: 2A (110V ~ 120V,
220V ~ 240V AC)
For 21 ~ 40 subs
P S-24E: 2A(110V~ 120V,
220V ~ 240V AC)
■ Sub stations
NA-A
NA-AN
NA-NE
N EM -10/C:
10-call
master
N EM -20/C:
20-call
master
N EM -30/C:
30-call
master
N EM -40/C; 40-call master
N EM -10/V C:
N EM -20A /C :
N EM -30A /C :
N EM -40A /C ;
10-call
master
20-call
master
30-call
master
40-cail master
N A -A : Desk/wal, single-gang
N A -A N : w/PRIV. button
N A -N E: Flush aluminum panei
N B -L: Ceiling mount
N A -T/A : Handset sub, single-gang
System o p tio ns
H ealth C are accesso ries
NBJ-40B
NB-U
IER -2:
Call extension speaker (at NEM)
N B -U :
Music adaptor. One per 40 subs.
Requires music source & amplifier.
N EW -5:
Dual-call adaptor. One per 5 subs.
Requires 12V DC power supply
N B J-20 : Call switching device for
NEM-10/C &20/C
N B J-40 ; for NEM-30/C & 40/C
N B J-20 B : for NEM-10A/C & 20A/C
N B J-40 B : for NEM-30A/C & 40A/C
NBY-4A
o
NAR-6A,
black
(3
NBY-1A
NAR-3
N B Y-4 A :
N R-4A S13;
N A R -3:
N A R -6A ;
N B Y-1 A
N B R -8 A :
N B R -7 A S:
N B R -7 A S-S:
NBR-7AS
NAR-2A,
white
Corridor call light, single-gang (for up to 3 subs)
same (for 4 to max.8 subs) (SOP) [-► See P.10]
Round bracket
Flush call button plate, single-gang
Flush metal jack plate, single-gang
Bedside manual call switch
Moisture resistant pullcord, single-gang
same (for use in a patient room) (SOP) [-►See P.8]
* NAR-3: Not available in USA
NR-4AS13, NBR-7AS-S: Not available in Europe
SOP (Special Order Product)
2
-