SYSTEM OUTLINE & COMPONENTS

The NEM-n/C & NEM-nA/C are master stations of Lamp Memory Intercom for

10 to max. 40 sub stations. NEM master station is capable of carrying out

communication by either open voice press-to-talk or lifting handset operation,
as well as transmit aii call to all the sub stations simultaneously.

2 -tfAp Sub stations

<, NA-A,

etc.

P A CK A G E CO N TEN TS

Master station N EM -n/C,
N EM -nA /C

(n = 10, 20, 30 & 40)

Mounting hardware
Installation & Operation Manual

1 common + 1 Indiv. -

To sub zone (s) ^

irZ i-

1^]

24V DC power supply
PS-2410A

(in USA, 10 ~ 20-call)

PS-24ME

(in Europe, 10 ~ 20-caii)

PS-24E

(10 - 40-call)

A

To avoid noise interference, be sure to

take G terminal on PS-24E to earth.

Note: For more than 40 to max. 120-station system,

SOP (*) master stations are available;

NEM-50 ~ 120, NEM-50A ~ 120A (/7.A for CE).

C O M P O N EN TS A V A ILA B LE

Press-to-talk master station • Master station w/handset

' i

• 24V DC power supply

For up to 20 subs

P S-241 O A : 1A (120V AC)
P S-24M E: 0.9A (220V AC)
P S-24E: 2A (110V ~ 120V,

220V ~ 240V AC)

For 21 ~ 40 subs

P S-24E: 2A(110V~ 120V,

220V ~ 240V AC)

■ Sub stations

NA-A

NA-AN

NA-NE

N EM -10/C:

10-call

master

N EM -20/C:

20-call

master

N EM -30/C:

30-call

master

N EM -40/C; 40-call master

N EM -10/V C:
N EM -20A /C :
N EM -30A /C :
N EM -40A /C ;

10-call

master

20-call

master

30-call

master

40-cail master

N A -A : Desk/wal, single-gang
N A -A N : w/PRIV. button
N A -N E: Flush aluminum panei
N B -L: Ceiling mount
N A -T/A : Handset sub, single-gang

System o p tio ns

H ealth C are accesso ries

NBJ-40B

NB-U

IER -2:

Call extension speaker (at NEM)

N B -U :

Music adaptor. One per 40 subs.

Requires music source & amplifier.

N EW -5:

Dual-call adaptor. One per 5 subs.

Requires 12V DC power supply

N B J-20 : Call switching device for

NEM-10/C &20/C

N B J-40 ; for NEM-30/C & 40/C
N B J-20 B : for NEM-10A/C & 20A/C
N B J-40 B : for NEM-30A/C & 40A/C

NBY-4A

o

NAR-6A,

black

(3

NBY-1A

NAR-3

N B Y-4 A :
N R-4A S13;
N A R -3:
N A R -6A ;
N B Y-1 A
N B R -8 A :
N B R -7 A S:
N B R -7 A S-S:

NBR-7AS

NAR-2A,

white

Corridor call light, single-gang (for up to 3 subs)
same (for 4 to max.8 subs) (SOP) [-► See P.10]

Round bracket
Flush call button plate, single-gang
Flush metal jack plate, single-gang
Bedside manual call switch
Moisture resistant pullcord, single-gang

same (for use in a patient room) (SOP) [-►See P.8]

* NAR-3: Not available in USA

NR-4AS13, NBR-7AS-S: Not available in Europe
SOP (Special Order Product)