104275

OWNER’S MANUAL

OFF

PILOT

IGNITOR

LOW

HIGH

TO SELECT

HEATING LEVEL

1.

Slightly press in control knob and
turn counterclockwise

to the

LOW or HIGH positions.

IMPORTANT:

Release downward

pressure while turning control knob.
Control knob will lock at the desired
position.

OPERATING
HEATER

Continued

Thermocouple

Figure 17 - Pilot

LIGHTING

INSTRUCTIONS

Figure 16 - Control Knob In The OFF
Position

1.

STOP! Read the safety information
page 10, column 3.

2.

Make sure equipment shutoff valve
is fully open.

3.

Turn control knob clockwise
to the OFF position.

4.

Wait five (5) minutes to clear out any
gas. Then smell for gas, including
near the floor. If you smell gas,
STOP! Follow “B” in the safety in-
formation. If you don’t smell gas, go
to the next step.

5.

Press in control knob, and turn coun-
terclockwise

to pilot position.

Keep control knob pressed for five
seconds.

Note:

You may be running this

heater for the first time after hook-
ing up to gas supply. If so, the con-
trol knob may need to be pressed in
for 30 seconds. This will allow air to
bleed from the gas system.
• If control knob does not pop up when

released, contact a qualified service
person or gas supplier for repairs.

6.

With control knob pressed in, push
down and release ignitor button. This
will light pilot. The pilot is attached to
the front of burner. If needed, keep
pressing ignitor button until pilot lights.

Ignitor Electrode

WARNING: When running

heater, set control knob at LOW
or HIGH locked positions. Never
set control knob between locked
positions. Poor combustion and
higher levels of carbon monox-
ide may result.

Control Knob

Piezo Ignitor Button

Note:

If pilot does not light, refer to

Troubleshooting, pages 13 through 15.
Also contact a qualified service person
or gas supplier for repairs. Until re-
pairs are made, light pilot with match,
see Manual Lighting Procedure
.

7.

Keep control knob pressed in for 10
seconds after lighting pilot. After 10
seconds, release control knob.

Note:

If pilot goes out, repeat steps

3 through 7.

CAUTION: Do not try to adjust

heating levels by using the equip-
ment shutoff valve.

Pilot Burner

LOW

OFF

PILOT

HIGH

OFF

PILOT

OFF

Control

Knobs

Burners

Figure 18 - Burner Patterns

TO TURN OFF GAS

TO APPLIANCE

MANUAL LIGHTING

PROCEDURE

1.

Remove front panel (see Figure 10,
page 8).

2.

Follow steps 1 through 5 under Light-
ing Instructions
.

3.

With control knob pressed in, strike
match. Hold match to pilot until pi-
lot lights.

4.

Keep control knob pressed in for 10
seconds after pilot is lit. After 10 sec-
onds, release control knob.

5.

Replace front panel.

Shutting Off Heater

Turn control knob clockwise

to

the OFF position.

Shutting Off Burner Only
(pilot stays lit)

Turn control knob clockwise to the
PILOT position.