TROUBLESHOOTING

WARNING: Turn off and unplug heater and let cool before servicing.

Only a qualified service person should service and repair heater.

CAUTION: Never use a wire, needle or similar object to clean

ODS/pilot. This can damage ODS/pilot unit.

Note:

All troubleshooting items are listed in order of operation.

POSSIBLE CAUSE

1. Ignitor electrode positioned wrong

2. Ignitor electrode broken

3. Ignitor electrode not connected to

ignitor cable

4. Ignitor cable pinched or wet

5. Piezo ignitor nut is loose

6. Broken ignitor cable

7. Bad piezo ignitor
1. Gas supply turned off or equipment

shutoff valve closed

2. Control knob not in PILOT posi-

tion

3. Control knob not pressed in while

in PILOT position

4. Air in gas lines when installed

5. Depleted gas supply

6. ODS/pilot is clogged

7. Gas regulator setting is not correct
1. Control knob not fully pressed in

2. Control knob not pressed in long

enough

3. Safety interlock system has been

triggered

4. Equipment shutoff valve not fully

open

5. Thermocouple connection loose

at control valve

6. Pilot flame not touching thermo-

couple, which allows thermocouple

to cool, causing pilot flame to go

out. This problem could be caused

by one or both of the following:

A) Low gas pressure

B) Dirty or partially clogged

ODS/pilot

7. Thermocouple damaged

8. Control valve damaged

OBSERVED PROBLEM

When ignitor button is pressed,

there is no spark at ODS/pilot

When ignitor button is pressed,

there is spark at ODS/pilot but

no ignition

ODS/pilot lights but flame goes

out when control knob is re-

leased

REMEDY

1. Replace pilot assembly

2. Replace pilot assembly

3. Reconnect ignitor cable

4. Free ignitor cable if pinched

by any metal or tubing. Keep

ignitor cable dry

5. Tighten nut holding piezo ignitor

to heater cabinet. Nut is located

inside heater cabinet at top

6. Replace ignitor cable

7. Replace piezo ignitor
1. Turn on gas supply or open

equipment shutoff valve

2. Turn control knob to PILOT

position

3. Press in control knob while in

PILOT position

4. Continue holding down control

knob. Repeat igniting operation

until air is removed

5. Contact local propane/LP gas

company

6. Clean ODS/pilot (see Cleaning

and Maintenance, page 13) or

replace ODS/pilot assembly

7. Replace gas regulator
1. Press in control knob fully

2. After ODS/pilot lights, keep con-

trol knob pressed in 30 seconds

3. Wait one minute for safety in-

terlock system to reset. Repeat

ignition operation

4. Fully open equipment shutoff

valve

5. Hand tighten until snug, then

tighten 1/4 turn more

6. A) Contact local propane/LP gas

company

B) Clean ODS/pilot (see Clean-

ing and Maintenance, page 13)

or replace ODS/pilot assembly

7. Replace pilot assembly

8. Replace control valve