Local codes, Unpacking, Safety information – Desa RH10PT User Manual

Page 4

Advertising
background image

www.desatech.com

110373-01E

4

1. Install and use heater with care. Follow all

local ordinances and codes. In the absence

of local ordinances and codes, refer to the

Standard for Storage and Handling of Lique-

fied Petroleum Gas, ANSI/NFPA 58 and the

Natural Gas Installation Code, CAN/CGA

B149.2. This instructs on the safe storage and

handling of propane/LP gases.

2. This appliance is only for use with the type

of gas indicated on the rating plate. This ap-

pliance is not convertible for use with other

gases.

3. This heater may be used in a recreational

enclosure or temporary construction work

enclosure with a remote refillable propane/LP

cylinder ONLY when the cylinder is located

outdoors and the heater is used with the hose

kit #LPA3090 (included with this heater).

NEVER bring a refillable propane/LP cylinder

indoors. A fire or explosion can occur causing

property damage, serious injury or death.

4. Use only the hose and factory preset regulator

provided with the heater. Use only replacement

pressure regulators and hose assemblies speci-

fied in this manual. See Accessories, page 17.

5. Inspect the hose before each use of the heater.

If it is evident there is excessive abrasion or

wear or the hose is cut, it must be replaced

prior to the heater being put into operation.

Use replacement hose assembly kit #LPA3090

(see Accessories, page 17).

6. Use only propane gas set up for vapor with-

drawal.

7. This heater shall not be installed in a bedroom

or bathroom.

8. This heater needs fresh, outside air ventilation

to run properly. This heater has an Oxygen

Depletion Sensing (ODS) safety shutoff sys-

tem. The ODS shuts down the heater if not

enough fresh air is available. You must provide

a minimum 10 square inches of ventilation air

for adequate combustion.

9. If heater shuts off, do not relight until you

provide fresh, outside air. If heater keeps

shutting off, have it serviced.

10. Keep all air openings in front and bottom of

heater clear and free of debris. This will insure

enough air for proper combustion.

SAFETY INFORMATION

Continued

11. Do not use heater if any part has been under

water. Immediately call a qualified service

technician to inspect the room heater and to

replace any part of the control system and any

gas control which has been under water.

12. Turn off and let cool before servicing. Only

a qualified service person should service and

repair heater.

13. Operating heater above elevations of 4,500

feet could cause pilot outage.

14. Turn off propane/LP supply when not in use.
15. Check heater for damage before each use. Do

not use a damaged heater.

16. Do not alter heater. Keep heater in its original

state.

17. Do not use heater if altered.
18. This heater can only be used in a recreational

or commercial enclosure with a window or

roof vent. This heater is not for outdoor use.

19. Before using the heater provide adequate

ventilation. An area of 10 square inches of

opening of a window or roof vent is needed

for adequate combustion and ventilation air.

LOCAL CODES

Install and use heater with care. Follow all lo-

cal codes. In the absence of local codes, use the

latest edition of National Fuel Gas Code, ANSI

Z223.1/NFPA 54*.
*Available from:

American National Standards Institute, Inc.

1430 Broadway

New York, NY 10018

National Fire Protection Association, Inc.

Batterymarch Park

Quincy, MA 02269

UNPACKING

1. Remove heater from carton.
2. Remove all protective packaging applied to

heater for shipment.

3. Check heater for any shipping damage. If

heater is damaged, promptly return to dealer

where you bought heater.