Checking gas connections, Connecting to gas supply, Warning – Desa VN2800BTA User Manual

Page 15: Continued

Advertising
background image

15

099570

IMPORTANT:

Hold pressure regulator with wrench when connecting it to gas piping

and/or fittings.

Pressure
Regulator

Tee Joint

Reducer
Bushing to
1/8" NPT

1/8" NPT
Plug Tap

Test

Gauge

Connection *

Tee Joint

Pipe

Nipple

Cap

Heater
Cabinet

1/2" NPT
Pipe Nipple

Figure 13 - Gas Connection

* An A.G.A. design certified manual shutoff valve with 1/8" NPT tap is an accept-
able alternative to test gauge connection. Purchase the optional A.G.A. design
certified manual shutoff valve from your dealer. See Accessories, page 30.

PRESSURE TESTING GAS SUPPLY PIPING SYSTEM

Test Pressures In Excess Of 1/2 PSIG

1. Disconnect heater and its individual manual shutoff valve from gas supply

piping system. Pressures in excess of 1/2 PSIG will damage heater regulator.

2. Cap off open end of gas pipe where manual shutoff valve was connected.
3. Pressurize supply piping system by either using compressed air or

opening main gas valve located on or near gas meter.

Continued

Ground Joint
Union

Note: Burner bracket
not shown for clarity

WARNING ICON

G 001

WARNING

Never use an open flame to check for a leak. Apply a mixture of
liquid soap and water to all joints. Bubbles forming show a leak.
Correct all leaks at once.

From Gas Meter

(4" W.C. to 10.5" W.C.

Pressure)

3" Minimum

Manual Shutoff

Valve *

Sediment

Trap

CHECKING

GAS

CONNECTIONS

WARNING ICON

G 001

WARNING

Test all gas piping and connections for leaks after installing or

servicing. Correct all leaks at once.

CONNECTING

TO GAS

SUPPLY

Continued