099570

Figure 21 - Incorrect Pilot Flame Pattern

INSPECTING

BURNER

Check pilot flame pattern and burner flame pattern often.

PILOT FLAME PATTERN

Figure 20 shows a correct pilot flame pattern. Figure 21 shows an incorrect pilot
flame pattern. The incorrect pilot flame is not touching the thermocouple. This will
cause the thermocouple to cool. When the thermocouple cools, the heater will shut
down.

Figure 20 - Correct Pilot Flame Pattern

Pilot Burner

Thermocouple

Thermocouple

Pilot Burner

TO TURN OFF GAS TO APPLIANCE

OPERATING

HEATER

Model VP2000BA

Continued

Shutting Off Heater

1. Turn control knob clockwise

Clockwise

to the PILOT position.

2. Press in control knob and turn clockwise

Clockwise

to the OFF position.

3. Turn off all electric power to the appliance if service is to be performed.

Shutting Off Burner Only (pilot stays lit)

1. Turn control knob clockwise

Clockwise

to the PILOT position.

MANUAL LIGHTING PROCEDURE

1. Remove front panel (see Figure 7, page 11).
2. Follow steps 1 through 5 under Lighting Instructions
, pages 20 and 21.
3. With control knob pressed in, strike match. Hold match to pilot until pilot

lights.

4. Keep control knob pressed in for 30 seconds after lighting pilot. After 30

seconds, release control knob.

5. Replace front panel.