Baud Rate

:2400, 4800, 9600, 19200Bit/S

Command Form

Byte 1

Byte 2 Byte 3

Byte 4

Byte 5 Byte 6

Byte 7

Synchronized Byt

e

Address Cod

e

Command Code

1

Command Code

2

Data Code

1

Data Code

Confirmation Cod

e

1.

All data in the Protocol as REX;

2. Synchronized Byte is 0FFH;

3. Address Code is the logical address number of cameras, Address Range

01H -0FFH;

3.

Form of Command Code as follows

Bit7

Bit6

Bit5

Bit4

Bit3

Bit2

Bit1

Bit0

Command

Code1

0

0

0

Auto Scan

0

Iris

Close

Iris Open

FocusNear

Command

Code2

Focus Far

ZoomWide

Zoom Tele

Down

Up

Left

Right 0

1. Command Code 1: BIT7, BIT6, BIT5, BIT3 is 0 without exception; (BIT4 is

auto-scanning control points 1/0

:ON/OFF) BIT2 Iris smaller (1 valid); BIT1 Iri

s larger (1 valid); BIT0 focus nearer (1 valid)

2. Command Code 2: BIT7 focus farther (1 valid); BIT6 & BIT5 for the control

of zoom, BIT6 far away from the object (1 valid), BIT5 near the object(1 vali

d); BIT4, BIT3, BIT2, BIT1 separately control the movement down, up, left,

right (1 valid); BIT0 is 0 without exception.

3. Data Code 1 controls the horizontal direction of speed 00-3FH

4. Data Code 2 controls the vertical direction of speed 00-3FH

5. Confirmation Code index [

(Byte 2 + Byte 3 + Byte 4 + Byte 5 + Byte 6)/

100H]

6. Confirmation Code = MOD [

(Byte 2 + Byte 3 + Byte 4 + Byte5 + Byte 6)

/100H]

7. Setting and Transferring of preset command:
(a)Set the command of preset positions

Byte 1

Byte 2

Byte 3 Byte4 Byte5 Byte 6

Byte 7

Synchronized Byte

Address Code

00H

03H

00H

Preset Point #

Confirmation

Code

(b)Transfer the command of preset positions

Byte 1

Byte 2

Byte 3 Byte 4 Byte 5 Byte 6

Byte 7

Synchronized Byte

Address Code

00H

07H

00H

Preset Point #

Confirmation

Code

Preset Point # Range

:00 - FFH

1. Turning the command of auxiliary swiches on and off:
(a)Turn the command of auxiliary switches on

Byte 1

Byte 2

Byte 3 Byte4

Byte5 Byte 6

Byte 7

Synchronized Byte

Address Code

00H

09H

00H

Auxiliary Switch

#

Confirmation

Code

(b)Turn the command of auxiliary switches off

Byte 1

Byte 2

Byte 3 Byte 4 Byte 5 Byte 6

Byte 7

Synchronized Byte

Address Code

00H

0BH

00H

Auxiliary Switch

#

Confirmation Cod

e

Auxiliary Switch # Range

:01 to 10

Product Features:
◇4.2”Vandalproof Pan/Tilt Dome Camera
◇1/3” SONY CCD + SONY DSP
◇540TVL
◇Super wide voltage board: 8-18V
◇High transparent vandalproof dome cover
◇5-15mm F2.2 2.0MP auto focus lens
◇With RS485 remote control, With 128 preset points
◇360° Horizontal endless rotation, 90° vertical movement
◇A panoramic view
◇Memory function at accidental power-off (Settings saved)