5

099156

PROPANE

SUPPLY

You must provide propane gas and propane tank(s).

Use this heater only with a propane vapor withdrawal supply system. See
Chapter 5 of the Standard for Storage and Handling of Liquified Petroleum Gas,
ANSI/NFPA 58.
Your local library or fire department will have this booklet.

The amount of propane gas ready for use from propane tanks varies. Two factors
decide this amount.

1. The amount of liquid propane gas in tank(s)
2. The temperature of tank(s)

The chart below shows the minimum number of 100-pound tanks needed to run
the heater. Connect tanks together with a manifold. Do not operate this product
with any tank smaller than 100 pounds.

Less gas is vaporized at lower temperatures. Two or more 100-pound tanks or one
larger tank may be needed in colder weather. Your local propane gas dealer will
help you select the proper supply system.

Average Temperature (

°

F)

At Tank Location

60

°

40

°

32

°

20

°

10

°

0

°

Number Of Tanks

2

2

3

3

3

3

SPECIFICATIONS

Rating(BTU/Hr)
Fuel
Fuel Consumption

Gallons/Hour
Pounds/Hour

Supply Pressure (To Regulator)

Maximum
Minimum, for input adjustment

Regulator Outlet Pressure
Weight (Pounds)
Shipping Weight (Pounds)
Size - L x W x H (Inches)

TC275

230,000
Propane Vapor Only

2.5
10.7

Tank Pressure
40 psi
10 psi
15
19
18

1

/

2

x 16 x 23

1

/

8

RCP275

275,000
Propane Vapor Only

3
12.75

Tank Pressure
40 psi
14 psi
15
19
18

1

/

2

x 16 x 23

1

/

8

VENTILATION

FRESH OUTSIDE AIR OPENING REQUIREMENTS

HEATER SIZE

SQUARE FEET OPENING

275,000 BTU/Hr
230,000 BTU/Hr

8.2
6.9

!

WARNING

Follow the minimum fresh outside air ventilation requirements.
If proper fresh outside air ventilation is not provided, carbon
monoxide poisoning can occur. Provide proper fresh outside
air ventilation before running heater.