Trouble- shooting, Warning – Desa RCP275 User Manual

Page 9

Advertising
background image

9

099156

SYMPTOM

Pilot fails
to light.

Pilot lights
but goes
out when
automatic
control valve
button
is released.

Burn rate
is low.

POSSIBLE CAUSE

1. Propane supply valve closed

on propane tank(s).

2. Excess-flow check valve

closed.

3. Air in gas line.

4. Blockage in pilot orifice.
5. Piezo ignition system not

sparking.

1. Not enough warm-up time.

2. Low gas pressure.

3. Thermocouple loose or

needs to be replaced.

4. Automatic control valve

needs to be replaced.

1. Main burner valve not fully

open.

2. Plugged gas orifices.
3. Low gas pressure.

4. Low fuel supply.

REMEDY

1. Open propane supply valve

slowly.

2. Close propane supply valve on

propane tank and reopen
slowly.

3. Allow several minutes to purge

air with automatic control
valve button depressed.

4. Replace pilot orifice.
5. Adjust ignitor electrode gap to

.120". Check wire lead for
damage. Replace piezo ignitor
and/or ignitor electrode as
necessary.

1. Relight, hold automatic control

valve button in 45 seconds.

2. Check propane tank(s) for

proper gas supply.

3. Tighten connection or replace

thermocouple.

4. Replace automatic control

valve.

1. Fully open main burner valve

by turning the valve handle
towards ON position until it
stops.

2. Replace gas orifice.
3. Check gas supply; check

regulator output.

4. Consult propane gas supplier.

TROUBLE-

SHOOTING

You may have further ques-
tions about this heater. If so,
contact DESA International’s
Technical Service Department
at 1-800-323-5190.

!

WARNING

Never attempt to service heater while it is connected to
propane supply, operating, or hot. Severe burns can occur.