Acoustics, Table 3, Operating and storage specifications – Dell PowerEdge M610x User Manual

Page 17: 4 acoustics

Advertising
background image

Dell

Dell PowerEdge M610x Technical Guide

12

Thermal specifications for the PowerEdge M610x are detailed in Table 3 along with other important
operating and storage information.

Table 3.

Operating and Storage Specifications

Temperature

Operating

10

o

to 35

o

C (50

o

to 95

o

F) with a maximum temperature gradation of

10

o

C per hour

Note: For altitudes above 2950 feet, the maximum operating
temperature is derated 1

o

F/500ft

Storage

-40

o

to 65

o

C (-40

o

to 149

o

F) with a maximum temperature gradation

of 20

o

C per hour

Relative Humidity

Operating

20% to 80% (noncondensing) with a maximum humidity gradation of
10% per hour

Storage

5% to 95% (noncondensing) with a maximum humidity gradation of
10% per hour

Maximum Vibration

Operating

0.26 Grms at 5-350 Hz in operational orientations

Storage

1.54 Grms at 10-250 Hz in all orientations

Maximum Shock

Operating

Half sine shock in all operational orientations of 31 G +/- 5% with a
pulse duration of 2.6 ms +/- 10%

Storage

Half sine shock on all six sides of 71 G +/- 5% with a pulse duration
of 2 ms +/- 10%

Altitude

Operating

-15.2m to 3048 m (-50 to 10,000 ft)
Note: For altitudes above 2950 ft, the maximum temperature is
derated 1

o

F/550 ft

Storage

-16 to 10,600 m (-50 to 35,000 ft)

5.4 Acoustics

Adherence to Dell’s high sound quality standards. Sound quality is different from
sound power level and sound pressure level in that it describes how humans respond
to annoyances in sound, like whistles, hums, etc. One of the sound quality metrics in
the Dell specification is prominence ratio of a tone.

Acoustical Performance of Typical Configuration. When installed in the M1000e

blade chassis, typical configuration

2

of M610x blade results in the following idle

2

Typical configuration means projected average quantity, type, capacity, speed, etc., of components. Configuration for which

data reported is listed in the following table.

Advertising