5 troubleshooting, 1 troubleshooting resources, 2 unable to open the web interface – Digi TransPort WR44 User Manual

Page 11: 3 unable to log in to the web interface, 6 specifications

Advertising
background image

TransPort® WR44 Installation Guide

Page 20

TransPort® WR44 Installation Guide

Page 21

5 Troubleshooting

5.1 Troubleshooting Resources

There are several resources available to you for support of your Digi product or resolving configuration

difficulties at Digi’s Support site, http://www.digi.com/support/. Try these troubleshooting steps to eliminate

your problem. After working through these steps and your problem is not solved, try the resources listed below.

1. Digi’s Support knowledge base: http://www.digi.com/support/kbase.

2. Digi TransPort support documents: http://ftp1.digi.com/support/documentation/transport/technicalnotes.htm.

3. If the knowledge base or support forums do not have the information you need, submit an Online Support

Request via: http://www.digi.com/support/eservice/login.jsp?p=true. You will need to create a user account if

one is not already set up.

When submitting a support request, please include a copy of the debug.txt file from the unit’s flash. This will

greatly improve the quality of the initial response you receive. Without this file, it is often very difficult for the

support team to provide accurate answers to your queries.

For instructions on how to download the debug.txt file from the unit, view the online document “QN24 -

Extracting the debug.txt file from a Digi TransPort or Sarian router”.

5.2 Unable to open the Web Interface

Ensure that the LAN cable is properly connected to the LAN port and that the “LAN” status indicator on the

front of the unit is illuminated. If it is not, then there is a problem with either the LAN cable or the device it is

connecting to. If the status indicator is illuminated, check that the PC can communicate with the unit. To do

this, open the Command Prompt window on your PC and enter the command “ping 192.168.1.1”. If you do not

get a response, then the problem could be one of the following:

• The IP address of the unit has been changed from its default of 192.168.1.1. Use the Digi TransPort

Connection Wizard (which can be downloaded from the Support area at Digi.com or the Digi Device

Discovery Tool). It can usually discover the unit on a network as long as the unit’s firewall has not been

enabled.

• PC IP configuration. The PC’s LAN interface that is connected to the unit should be configured to “Obtain

an IP address automatically”. If required, the Digi TransPort Connection Wizard can be used to configure

the PC.

• Check the PC’s LAN connection and any LAN device (e.g. Ethernet switch) that is used to interconnect to

the unit.

• Refresh the PC’s IP settings by opening a command window and enter “ipconfig /release” then “ipconfig /

renew”.

• ARP resolution. Clear the PC’s ARP cache with the command “arp –d *”, then retry the ping command. If

you do get a response but are unable to view the Web Interface, then there is most likely a problem with

your web browser configuration.

5.3 Unable to log in to the Web Interface

Access to the unit can be achieved via any of the asynchronous serial ports. Connect your PC to the unit using

a “straight through” RS232 serial cable. This will allow you to change the configuration via the Command Line

Interface (CLI). Please refer to the Digi TransPort User Guide for information on how to use the CLI. The User

Guide can be downloaded from the Digi Support site. If you have further questions about your product please

contact Digi Technical Support (see page 2 for contact information).

6 Specifications

Specifications

Digi TransPort WR44 / WR44 R

General Features:
Dimensions

(L x W x H)

5.7” x 8.3” x 1.6”

(145 mm x 210 mm x 40 mm)

Weight

1.98 lb (0.9Kg)

Other

Standard dual SIM (SIM protection cover option); Conformal coating (option)

RF Features:
GSM Models
GPRS

GPRS Class 10, Quadband 850/900/1800/1900 MHz

EDGE

GPRS Class 10/EDGE Class 10, Quadband 850/900/1800/1900 MHz

HSDPA/HSUPA/UMTS

850/900/1900/2100 MHz with Rx Diversity

CDMA Models
CDMA/EV-DO Rev A

Dualband 800/1900 MHz with Rx Diversity; Optional multi-mode GSM/EV-

DO Gobi support; 450 MHz, 3.1 Mbps down / 1.8 Mbps up, R-UIM support

Power Requirements:
Power Input

11 - 58 VDC

Power Supply

100 - 240 VAC 50/60 Hz with barrel connector, Optional Molex connector

with bare wire leads

Power Consumption

15W @ 12 VDC to WR44

Environmental:
Operating

Temperature

WR44: 0° C to +60° C
WR44 Extended Temp/WR44R:

-40° C to +75° C; -20° C to +75° C (Wi-Fi models only)
Reduced cellular performance may occur above +60° C

Relative Humidity

20% to 95% (non-condensing)

Ethernet Isolation

1.5 kV

Serial Port Protection

(ESD)

1.5 kV

Approvals:
Mobile Certifications - GSM/

UMTS

PTCRB, NAPRD.03, GCF-CC, R&TTE, EN 301 511

Mobile Certifications - CDMA/

EV-DO

CDG TIA/EIA-690, CDG TIA/EIA-98-E

Wireless Carrier Certifications

Certified by most major carriers. See www.digi.com for current listing.

Safety

UL 60950, CSA 22.2 No. 60950, EN60950

Emissions / Immunity

CE, FCC Part 15 Class B, AS/NZS CISPR 22, EN55022 Class A

Vehicle Related Certifications

2004/104/EC, 2005/49/EC, 2005/83/EC, 2006/28/EC, 72/245/EEC,

ISO7637-2 Class C

Advertising