2-6 AR-B9612 User’s Guide
(1) Receiver Buffer Register (RBR)
Bit 0-7: Received data byte (Read Only)
(2) Transmitter Holding Register (THR)
Bit 0-7: Transmitter holding data byte (Write Only)
(3) Interrupt Enable Register (IER)
Bit 0: Enable Received Data Available Interrupt (ERBFI) 
Bit 1: Enable Transmitter Holding Empty Interrupt (ETBEI) 
Bit 2: Enable Receiver Line Status Interrupt (ELSI) 
Bit 3: Enable MODEM Status Interrupt (EDSSI) 
Bit 4: Must be 0 
Bit 5: Must be 0 
Bit 6: Must be 0 
Bit 7: Must be 0 
(4) Interrupt Identification Register (IIR)
Bit 0: “0” if Interrupt Pending 
Bit 1: Interrupt ID Bit 0 
Bit 2: Interrupt ID Bit 1 
Bit 3: Must be 0 
Bit 4: Must be 0 
Bit 5: Must be 0 
Bit 6: Must be 0 
Bit 7: Must be 0 
(5) Line Control Register (LCR)
Bit 0: Word Length Select Bit 0 (WLS0) 
Bit 1: Word Length Select Bit 1 (WLS1) 
WLS1
WLS0
Word Length
0
0
5 Bits
0
1
6 Bits
1
0
7 Bits
1
1
8 Bits
Bit 2: Number of Stop Bit (STB) 
Bit 3: Parity Enable (PEN) 
Bit 4: Even Parity Select (EPS) 
Bit 5: Stick Parity 
Bit 6: Set Break 
Bit 7: Divisor Latch Access Bit (DLAB)