Unvented natural gas log heater desa international, Wiring diagram, Specifications – Desa CFS18NRA User Manual

Page 24: Technical service, Service hints

Advertising
background image

24

104416

UNVENTED NATURAL GAS LOG HEATER

DESA INTERNATIONAL

WIRING DIAGRAM

AUT

O

OFF

ON

Thermopile

SPECIFICATIONS

18" Variable

24" Variable

30" Variable

Btu (Variable)

16,000/26,000

20,000/33,000

21,500/36,000

Type Gas

Natural Gas Only

Natural Gas Only

Natural Gas Only

Ignition

Piezo

Piezo

Piezo

Manifold Pressure

3.4" W.C.

3.4" W.C.

3.4" W.C.

Inlet Gas Pressure (in. of water)

Maximum

10.5"

10.5"

10.5"

Minimum*

5"

5"

5"

Shipping Weight

32 lbs.

34 lbs.

36 lbs.

* For purpose of input adjustment

TECHNICAL
SERVICE

You may have further questions about in-
stallation, operation, or troubleshooting. If
so, contact DESA International’s Technical
Service Department at 1-800-DESA LOG
(1-800-337-2564).

You can also visit DESA International’s
Technical Services web site at

www.desatech.com.

SERVICE HINTS

When Gas Pressure Is Too Low

• pilot will not stay lit

• burners will have delayed ignition

• heater will not produce specified heat

When Gas Quality Is Bad

pilot will not stay lit

burners will produce flames and soot

heater will backfire when lit

You may feel your gas pressure is too low or
gas quality is bad. If so, contact your local
natural gas supplier.

Advertising