Power on utilities – AMT Datasouth M5DT Plus User Manual

Page 25

Advertising
background image

23

4. Power on Utilities

There are six power-on utilities to set up and test printer hardware. These utilities are

activated by pressing FEED button and by turning on the printer power simultaneously.

The utilities are listed as below:

1. Gap/Black Mark sensor calibration

2. Gap/black mark sensor calibration, Self-test and Dump mode

3. Printer

initialization

4. Black mark sensor calibration

5. Gap sensor calibration

6. Skip

AUTO.BAS

4.1 Gap/Black Mark Sensor Calibration

Gap/black mark sensor sensitivity should be calibrated at the following conditions:

1. A brand new printer

2. Change label stock.

3. Printer initialization.

Please follow the steps below to calibrate the gap/black sensor:

1.Turn off the power switch.

2. Hold on the button then turn on the power switch.

3 Release the button when LED becomes

red

and blinking. (Any red will do during the 5

blinks).

It will calibrate the gap/black mark sensor sensitivity.
The LED color will be changed as following order

Amber

red

(5 blinks)

amber (5 blinks)

green (5 blinks)

green/amber (5

blinks)

red/amber (5 blinks)

solid green

It calibrates the sensor and measures the label length.

Note:

Please select gap or black mark sensor by GAP or BLINE command prior to

calibrate the sensor.

For more information about GAP and BLINE command, please refer to

programming manual.

Advertising