User’s Manual
Item
Option
Description
Serial Port
Disabled
Enabled[Default]
Enable or Disable Serial Port
(COM).
Change Settings
Auto[Default]
IO=2F8h; IRQ=3;
IO=3F8h; IRQ=3,4,5,6,7,9,10,11,12;
IO=2F8h; IRQ=3,4,5,6,7,9,10,11,12;
IO=3E8h; IRQ=3,4,5,6,7,9,10,11,12;
IO=2E8h; IRQ=3,4,5,6,7,9,10,11,12;
Select an optimal setting for
Super IO device.
3.6.2.7 HW Monitor
The H/W Monitor shows the operating temperature, fan speeds and system voltages.
Item
Options
Description
Smart Fan 1 Mode
Full on Mode
Automatic Mode[Default]
Smart Fan 1 Mode Select.
Fan off temperature limit
0-127
Fan will off when temperature lower than this
limit. [0-127]
Fan start temperature limit
0-127
Fan will work when temperature higher than
this limit. [0-127]
Fan start PWM
0-255
Fan will stat with this PWM value. [0-255]
PWM SLOPE SETTING
0-127
PWM SLOPE Value. [0-127]