Fireplace installation – Desa (V)KC42NE SERIE User Manual

Page 20

Advertising
background image

20

www.desatech.com

116240-01B

Open

Closed

Equipment

Shutoff

Valve

Figure 34 - Checking Gas Joints for Propane/LP Gas Fireplace

Propane/LP

Supply Tank

Gas Valve

Equipment

Shutoff

Valve

Figure 33 - Equipment Shutoff Valve

Figure 35 - Checking Gas Joints for Natural Gas Fireplace

Gas

Meter

Gas Valve

Equipment

Shutoff

Valve

FIREPLACE INSTALLATION

Continued

FIREPLACE INSTALLATION

Checking Gas Connections (Cont.)
Removing/Replacing Glass Door

Test Pressures Equal To or Less Than 1/2 PSIG (3.5 kPa)

1. Close equipment shutoff valve (see Figure 33).
2. Pressurize supply piping system by either opening propane/LP

supply tank valve for propane/LP gas fireplace or opening main

gas valve located on or near gas meter for natural gas fireplace

or using compressed air.

3. Check all joints from propane/LP supply tank or gas meter to equip-

ment shutoff valve (see Figure 34 for propane/LP or Figure 35 for

natural gas). Apply noncorrosive leak detection fluid to all joints.

Bubbles forming show a leak. Correct all leaks at once.

Pressure Testing Fireplace Gas Connections

1. Open equipment shutoff valve (see Figure 33).
2. Open propane/LP supply tank valve for propane/LP fireplace

or main gas valve located on or near gas meter for natural

gas fireplace.

3. Make sure control knob of fireplace is in the OFF position.
4. Check all joints from equipment shutoff valve to gas valve (see

Figure 34 for propane/LP or Figure 35 for natural gas). Apply

noncorrosive leak detection fluid to all joints. Bubbles forming

show a leak. Correct all leaks at once.

5. Light fireplace (see Operating Fireplace, page 23). Check all

other internal joints for leaks.

6. Turn off fireplace (see To Turn Off Gas to Appliance, page 24).

REMOVING/REPLACING GLASS DOOR

CAUTION: Do not operate this fireplace with a

broken glass door panel or without the glass door

panel securely in place. For replacement part infor-

mation see

Replacement Parts, page 28.

CAUTION: Wear gloves and safety glasses while

handling or removing broken glass. Do not remove if

glass is hot. Keep children and pets away from glass.

WARNING: If fireplace has been running, turn off

and unplug fireplace. Let cool before removing glass

door or louvers.

Removing Louver Panels

Remove the top and bottom louver panels by simultaneously pulling

both top end spring latches towards the center of the appliance until

they are disengaged from the locating holes (see Figure 36). Repeat

for bottom spring latches and pull the louvers outward. To install or

replace items removed, simply reverse the procedures above.

Figure 36 - Removing Louver Panel

Louver Panel

Spring Latch

Advertising