Portable forced air heaters, Storing, transporting, or shipping, Operation – Desa 35 User Manual

Page 4: Preventative maintenance schedule

Advertising
background image

4

102388

PORTABLE FORCED AIR HEATERS

35,000, 50,000, And 55,000 Btu/Hr H.S.I. Series

Item

Fuel tank

Air output and lint filters

Air intake filter

Fuel filter

Ignitor

Fan blades

Motor

WARNING: Never service

heater while it is plugged in, op-
erating, or hot. Severe burns and
electrical shock can occur.

STORING,
TRANSPORTING,
OR SHIPPING

Note:

If shipping, transport companies re-

quire fuel tanks to be empty.

1.

Drain fuel tank. Drain fuel through fuel
cap opening. Be sure all fuel is removed.

2.

If any debris is noted in old fuel, add 1
or 2 quarts of clean kerosene to tank,
stir, and drain again. This will prevent
excess debris from clogging filters dur-
ing future use.

3.

Replace fuel cap. Properly dispose of old
and dirty fuel. Check with local auto-
motive service stations that recycle oil.

4.

If storing, store heater in dry place.
Make sure storage place is free of dust
and corrosive fumes.

IMPORTANT:

Do not store kerosene over

summer months for use during next heating
season. Using old fuel could damage heater.

WARNING: Review and un-

derstand the warnings in the
Safety Information Section, page
2. They are needed to safely op-
erate this heater. Follow all local
codes when using this heater.

TO START HEATER

1.

Follow all ventilation and safety in-
formation.

2.

Fill fuel tank with kerosene or No. 1
fuel oil.

3.

Attach fuel cap.

4.

Plug power cord of heater into three-
prong, grounded extension cord. Exten-
sion cord must be at least six feet long.

OPERATION

Extension Cord Wire Size
Requirements

• 6 to 10 feet long, use 18 AWG rated

cord

• 11 to 100 feet long, use 16 AWG

rated cord

• 101 to 200 feet long, use 14 AWG

rated cord

5.

Plug extension cord into standard 120
volt/60 hertz, three-hole, grounded out-
let.

Note:

Ignitor will preheat for five

seconds then heater will start.

TO STOP HEATER

Unplug extension cord from outlet.

TO RESTART HEATER

1.

Unplug extension cord from outlet and
wait 10 seconds (two minutes if heater
has been running).

2.

Plug extension cord into standard 120
volt/60 hertz, three hole, grounded out-
let.

Note:

Ignitor will preheat for five

seconds then heater will start.

PREVENTATIVE
MAINTENANCE
SCHEDULE

How To

See Storing, Transporting, or Shipping,
above.

See Air Output, Air Intake, and Lint Filters,
page 6.

See Air Output, Air Intake, and Lint Filters,
page 6.

See Fuel Filter, page 7.

See Fan, page 6.

How Often

Flush every 150-200 hours of operation or
as needed.

Replace every 500 hours of operation or
once a year.

Wash and dry with soap and water every
500 hours of operation or replace as needed.

Clean twice a heating season or replace as
needed.

No maintenance required.

Clean each season or as needed.

Not required/permanently lubricated.

Advertising