Surface travel is stopped automatically in the fully opened and closed positions by limit switches that are properly adjusted

at Da-Lite. Should it be necessary to adjust for more or less drop of picture, proceed in the following manner:

NOTE: Use a screw driver or 5/32" allen wrench to make

adjustments.

More screen drop

1. Place operating switch in “down” position.

2. When the screen stops, turn the white “down” limit knob

(Fig.4) one-quarter turn counterclockwise. Test by raising
picture surface approximately two feet, then lower again.
Repeat until desired picture surface position is attained.

Less screen drop

1. Raise picture surface approximately two feet

above desired level.

2. Place operating switch in “off” position.

3. Turn the white “down” limit knob (Fig.4) one-quarter turn

clockwise. Test by raising picture surface approximately two
feet, then lower again. Repeat until desired picture surface
position is attained.

CAUTION! Do not adjust for more drop than what was
ordered. At least 1-1/2 wraps of fabric must remain on the
roller. This screen comes standard with 0" or 2" black at
the top. See the specification data sheet for details.

ATTENTION! N'effectuez pas de réglage pour obtenir un
déroulement supérieur à celui commandé. Au moins 1 à
1/2 tour de toile doit être maintenu sur le cylindre. Cet
écran est doté de série d'une bande noire supérieure de 0
cm (0 po) ou 5 cm (2 po). Consultez la fiche technique
pour plus de renseignements.

Boardroom Electrol

®

Installation 120V Screens

Screen Adjustment For 120V Screens

Operating switch and
plate furnished with
screen. (SPDT with
center off)

Black

(Down)

Up

Down

Red

(Up)

Side View of
Switch & Box

Black (Do

wn)

R

ed (Up)

Whit

e (Common)

AC Common

Black With
Yellow

AC Hot
120V. AC 60 HZ
1 AMP. MAX.

NOTE: A single switch cannot be used to operate more than
one screen. Contact the factory for further information.

This switch cannot be used with L.V.C.

120V Wiring Diagram

Figure 4

To junction box mounted in
screen case, in which internal
wiriing teminates in white, black,
and red leads.

In multiple control
installations the switch
is replaced by the low
voltage control,
operated from push
button stations.

Black
White
Red

Normally
Closed
Door
Limit
Switch

Motor

Off

Access
Door

Adjustment Red

Knob "Up"

Adjustment White

Knob "Down"

Fabric
Door

Screen

Motor