5

Motorized Scenic Roller Installation

120V / 240V Wall Switch

Wiring Diagram

White - (Common)

Black - (Down)

Red - (Up)

Front

Of

Wall

Switch

Back

Of

Wall

Switch

UP

STOP

DOWN

Optional RF Remote
Connection

Not Used

NOTE: 20-24AWG wire recommended for

connecting wall switch to sychronization
controller.

IMPORTANT! The wall switch terminal block can be connected inside the wiring compartment. The controller does not need to be

removed from the junction box unless an RF remote is being connected. Use caution when removing the controller from the box as it

is easily damaged.