Appendix A: Screen Adjustment for Type 2 Motor (LT suffix in Part Number)

No manual limit adjustments
on end of motor

RJ-22 cable

3-wire connection

TYPE 2 MOTOR

TYPE 2 WALL SWITCH

1. Remove the cover plate from the 3-button wall switch and remove

the switch from the junction box.

2. Locate small 3-position switch on back of wall switch.

3. To adjust the down limit switch, slide the 3-position switch to the

down position. Press and hold the down button to run the screen
down to the desired stop position. Release the button to stop the
screen. DO NOT PUSH THE STOP BUTTON.

CAUTION: Do not adjust for more drop than what was ordered.
At least 1–1/2 wraps of fabric must remain on the roller. This
screen comes standard with 12" black at the top.

ATTENTION! N'effectuez pas de réglage pour obtenir un
déroulement supérieur à celui commandé. Au moins 1 à 1/2 tour
de toile doit être maintenu sur le cylindre. Ce écran est doté de
série d'une bande noire supérieure de 30,5 cm (12 po).

4. When the screen is in the desired down position, slide the 3-position

switch to the off (center) position. The down limit switch is now set.

5. To adjust the up limit switch, slide the 3-position switch to the up

position. Press and hold the up button to run the screen up to the
desired stop position. Release the button to stop the screen. DO
NOT PUSH THE STOP BUTTON.

CAUTION: Adjusting the limits by more than 6” can cause the
screen surface to lose proper tensioning.

ATTENTION! Le fait d'ajouter plus de 15 cm (6po) aux
interrupteurs de fin de course peut faire perdre la bonne
tension à la surface de l'écran.

6. When the screen is in the desired up position, slide the 3-position

switch to the off (center) position. The up limit switch is now set.

7. To test limit switch setting, make sure the 3-position switch is in the

off (center) position. Press and release the up or down button on the
wall switch to operate the screen.

8. Replace switch and cover plate on the wall.

NOTE:

If stop button is pressed, the wall switch will reverse

direction. To correct this, press the stop button again. This will
reset the switch. You will have to reset both the up and the down
limit settings.

IMPORTANT NOTE: The wall switch is REQUIRED to make any
limit switch adjustments, even if a third party control system is
used. Therefore, it is advised to wire the switch or provide a
4-conductor connection that is accessible.