Appendix A: Screen Adjustment for Type 3 Motor (LS suffix in Part Number)

TYPE 3 MOTOR

No manual limit adjustments
on end of motor

RJ-45 cable

3-wire connection

TYPE 3 WALL SWITCH

1. Locate the wall switch and remove the cover plate from the wall

switch and remove the switch from the junction box.

2. Locate the two tactile buttons on the back of the switch. They are

black round buttons on silver plates.

3. To adjust the down limit switch, press and hold the down tactile

button until the LED on the back of the switch turns solid red. This

will put the motor in limit set mode. Turn the wall switch over and

use the down button on the front of the switch. Press and hold the
down button until the desired down position is reached. If you travel
too far down, press the up button to move the screen upward. If you
press and let go of either the up or down buttons, the motor will do
a small jog in that direction for fine adjustment of the screen. Once
the desired position is reached, turn the switch over; press and hold
the down tactile button until the LED on back of switch blinks red
twice. The down limit is now set.

CAUTION: Do not adjust for more drop than what was ordered.
At least 1–1/2 wraps of fabric must remain on the roller. This

screen comes standard with 12" black at the top.

ATTENTION! N'effectuez pas de réglage pour obtenir un

déroulement supérieur à celui commandé. Au moins 1 à 1/2
tour de toile doit être maintenu sur le cylindre. Ce écran est
doté de série d'une bande noire supérieure de 30,5 cm (12 po).

NOTE: If the screen is in limit set mode and no buttons are pushed

for 20 seconds, the LED on the back of the wall switch will turn off,
the motor will return to run mode and no changes will be saved. If
this occurs, return to step 3 for down limit adjustment or step 4 for
up limit adjustment.

4. To adjust the up limit switch, press and hold the up tactile button

until the LED on the back of the switch turns solid green. This will
put the motor in limit set mode. Turn the wall switch over and use
the up button on the front of the switch. Press and hold the up
button until the desired up position is reached. If you travel too far
up, press the down button to move the screen downward. If you
press and let go of either the up or down buttons, the motor will do
a small jog in that direction for fine adjustment of the screen. Once
the desired position is reached, turn the switch over; press and hold

Bus

Down Limit

Tactile Button

Up Limit

Tactile Button

Back of Wall Switch

5V

CO

M

BUS

the up tactile button until the LED on back of switch blinks green
twice. The up limit is now set.

CAUTION: Adjusting the limits by more than 6” can cause the

screen surface to lose proper tensioning.

ATTENTION! Le fait d'ajouter plus de 15 cm (6po) aux

interrupteurs de fin de course peut faire perdre la bonne
tension à la surface de l'écran.

5. To test the limit switch settings, press and release the up or down

buttons on the switch to operate the screen.

6. Replace the switch and cover plate on the wall.

IMPORTANT NOTE: The wall switch is REQUIRED to make any
limit switch adjustments, even if a third party control system is
used. Therefore, it is advised to wire the switch or provide a

3-conductor connection that is accessible.