Repair information, Hydraulically driven centrifugal pumps – Delavan M125 User Manual

Page 7

Advertising
background image

Toll Free: 1-866-DELAVAN (335-2826) • PH: 612-333-3189 • Toll Free Fax: 1-888-726-5906 • Fax: 612-333-3231

Document HD Magnum Install 3.15.06

Hydraulically Driven Centrifugal Pumps

7

Repair Information

Replacing Hydraulic Motor Shaft Seal

1. Remove the four bolts on the

volute using a 9/16” wrench.
Fig. 1.

2. Remove the impeller nut

using a 3/4” socket. Hold the
impeller from turning by using
a screwdriver in vanes of the
impeller. Fig. 2.

3. Remove the impeller key using

pliers and screwdriver. Fig.
3.

4. Remove the spring assembly

from the shaft by pulling it off
with your hand. Fig. 4.

5. Work the outer seal half off

the shaft carefully with a
screwdriver. Fig. 5.

6. Work the inner seal half off out

of the housing carefully with a
small flat bladed screwdriver.
Break the ceramic with a
hammer and screwdriver if
necessary to remove. Fig. 6.

7. Reassemble with a new seal

kit. Install new ceramic seal
half in the bearing housing
with the ceramic facing out.

8. Carefully slide the carbon seal

half over the shaft so that the
carbon and ceramic are facing
each other.

9. Complete the seal assembly

in the reverse order shown.
Install a new o-ring on the
frame housing for the volute.

Fig. 1

Fig. 2

Fig. 3

Fig. 4

Fig. 5

Fig. 6

Replacing Pump Mechanical Seal

1. Remove motor from the

pump using a 9/16” wrench.
Fig. 7.

2. Using an allen wrench,

unscrew the four allen bolts
and remove the front flange.
Fig. 8.

3. Remove the mechanical

seal half and o-ring from the
flange. Fig. 9.

4. Remove the mechanical

seal half, o-ring, spacer and
spring from the motor.

5. Reassemble with a new seal

kit in the reverse order. Fig.
10.

Fig. 7

Fig. 8

Fig. 9

Fig. 10

Advertising