Service - 74

FX25 Operator’s

Manual

10 Hour

CMW

Check Water Pump Belt Tension

Check belt every 10 hours for correct tension,
damage or wear. Contact your Ditch Witch dealer
for adjustment or belt replacement.

To check

1.

Turn ignition to STOP and remove key.

2.

Apply moderate thumb pressure to belt
between pulleys.

3.

Belt is properly tensioned when deflection is
.125-.25” (3-6 mm).

Clean Vacuum Air Filter

Clean filter every 10 hours or as needed.

To clean filter:

1.

Remove filter from canister.

2.

Run low pressure water into inside of filter.

3.

Allow filter to dry completely before returning to canister.

Breathing

crystalline silica dust may cause
lung disease. Cutting, drilling, or
working materials such as
concrete, sand, or rock

containing quartz may result in exposure to
silica dust. Use dust control methods or
appropriate breathing protection when
exposed to silica dust.

NOTICE: Do not use high pressure water to clean filter. Filter will be damaged.