Fx25 operator’s manual – Ditch Witch FX25 User Manual
Page 91
Advertising
Service - 90
FX25 Operator’s
Manual
As Needed
CMW
Change Blower Relief Air Filter
Check air filter whenever vacuum gauge goes
over 16” (406 mm) of mercury. Change as
needed.
1.
Remove clamp.
2.
Remove filter and discard.
3.
Install new filter.
4.
Replace clamp.
Empty Cyclonic Separator Canister
Empty cyclonic separator canister (2) as needed.
Open door and dump tank. Clean out cyclone
through upper access door (1) as needed.
NOTICE: Operating system above 16” (406
mm) of mercury may result in blower damage.
IMPORTANT: Depressurize tank before
emptying cyclonic canister, cleaning filter,
clearing hoses or opening any doors.
j32om053h.eps