Mh7399 – DuraVent DuraTech & DuraChimney II European Copper Pots User Manual

Page 2

Advertising
background image

2

Figure 1

MH7399

Read through these instructions before

beginning your installation. Failure to

install as described in these instructions

will void the manufacturer’s warranty and

may have an effect on your homeowner’s

insurance and UL listing status. Keep these

instructions for future reference.

These installation instructions apply to installing

the European Copper Chimney Pots King

or Bishop model shroud/pot onto DuraTech

(10”-16” diameter) or DuraChimney II (10”-14”

diameter) chimney. Refer to the full DuraTech

or DuraChimney II installation instructions

(L151, or L180) for complete details on properly

installing a DuraTech or DuraChimney II system.

Refer to European Copper Pots installation

instructions for details about proper installation

of their products. Currently, only the King and

Bishop models are listed for use with DuraTech

and DuraChimney II.

Listing: UL listed to UL 103 and ULC S604

standards.

To install a European Copper Chimney Pot

(King or Bishop model) properly on DuraTech

or DuraChimney II, the standard chimney cap is

removed from the system and replaced with a

dedicated, UL listed Adapter. The Adapter must

be used with DuraTech or DuraChimney II in

order to maintain the UL listing of the system.

Install DuraChimney II in accordance with

the DuraChimney II Installation Instructions,

L180. For DuraTech, install the chimney in

accordance with the DuraTech Installation

Instructions, L151. These instructions are

available from DuraVent’s website, www.

duravent.com.

Figure 1 shows the Adapter itself. The same

Adapters are used for both DuraTech and

DuraChimney II. There are two different

Adapter models, each available for the

different chimney diameters; one dedicated

to the King model, and a separate Adapter

dedicated for the Bishop model. Use only the

correct Adapter model and diameter for the Pot

and chimney diameter used for your system

(e.g. use only the 14” Bishop Adapter for

installation of a Bishop Pot on a 14” chimney

system). Figure 2 shows the overall completed

installation of the European Copper King

model onto DuraChimney II using the Adapter.

Figure 3 shows attachment detail of the

Adapter for DuraChimney II. Figure 4 shows

the overall installation of the King model onto

DuraTech chimney, and Figure 5 shows the

attachment detail of the Adapter for DuraTech.

Installation of the Bishop model is the same as

that of the King, except for using the dedicated

Bishop Adapter.

The top of the chimney pipe for both DuraTech

and DuraChimney II must extend between

2” and 4.5” above the collar of the Chase

Top Flashing (or Chase Top Collar). For

DuraChimney II, install the required Storm

Collar on the outer wall of the chimney, as

normal (Figure 3). For DuraTech chimney, do

not install the Storm collar (Figure 5).

Advertising