Numbers. The UL Catalog Numbers will be

referred to within the instructions, as an aid

to assembly, however for ordering, use the

stock numbers shown in the Chimney Products

Catalog. Practice good workmanship. Sloppy

work could jeopardize your chimney’s safety.

Keep electrical wiring and insulation away from

all chimneys and stovepipes.

CHIMNEY DIAMETER

Follow the appliance manufacturer’s

instructions to determine chimney diameter

and clearances between combustible materials

and your heating appliance. Never choose a

chimney with an inside diameter smaller than

the appliance flue gas outlet. To calculate the

chimney’s outside diameter, add 4 inches to

the inside diameter.

CHIMNEY HEIGHT

The National Fire Protection Association

Standard #211 states: “Chimneys shall extend

at least three feet above the highest point

where it passes through the roof of a building,

and at least two feet higher than any portion

of a building within ten feet.” (Figure 1).

DuraPlus may be installed up to 35 feet high.

If a chimney is installed higher than 35 feet, a

supporting Elbow Strap must be placed every

8 feet. If the chimney extends more than 4

feet above the roof, an Extended Roof Bracket

must be used. Subtract 1-1/2 inches from

each Chimney Section’s length to calculate

installed length.

CHIMNEY PLACEMENT

When deciding the location of your chimney,

try to minimize the alteration and reframing of

structural components of the building.

TABLE 1

DURAPLUS (SDP) PARTS WITH UL CATALOG NUMBERS

UL Cat # Part

UL Cat # Part

SDP-P

Chimney Sections

SDP-TS

Tee Support Bracket

SDP-T

Tee

SDP-IS

Insulation Shield

SDP-F

Flashing

SDP-FRS Firestop Radiation Shield

SDP-TF

Flat Roof Flashing

SDP-SC

Storm Collar

SDP-S

Flat Ceiling Support Box

SDP-WS Wall Strap

SDP-RS

Round Ceiling Support Box

SDP-ES

Elbow Strap

SDP-SB

Square Ceiling Support Box

SDP-RSA Extended Roof Bracket

SDP-WT

Wall Thimble

SDP-AP

Anchor Plate

SDP-C

Chimney Cap

Figure 1

2 FEET MIN. ABOVE HIGHEST

POINT OF ROOF WITHIN

10 FEET

3 FEET MIN.

FROM ROOF

PENETRATION

10 FEET

MINIMUM CHIMNEY HEIGHT