Signal flow

Note: Analog inputs are balanced with pin 2 hot, pin 3 cold and pin 1 GND. For unbalanced
inputs just connect to pin 2 and tie pin 3 to GND.

Function Switches

Note: Some configurations require long settling times of up to several seconds after changing
switch positions.

Note: The powerup sequence and initial calibration of the unit takes about 20 seconds after
power is applied.

Clock Section

INT /EXT:

Selects internal or external clock source. LOCK LED is lit

when A/D converter is locked to external clock.

OPTIC / BNC:

Selects external clock between optical and BNC formats.

Sample Rate Section

64 / 128:

Selects oversampling ratio. 128 position does not allow
2FS PCM generation (error light on).

1FS / 2FS:

Selects the sample rate for PCM data. FS is the base
frequency (see 44.1 / 48 switch). 2FS position will mute
outputs when the oversampling ratio is set to 128.

44.1 / 48:

Selects the base frequency (only 44.1kHz is allowed for
DSD outputs and inputs).

A/D

Conversion

DC Removal

DSD

DSD

DSD

PCM

PCM

DSD (Optical)

Analog

DSD (RAW/SDIF3)

(shared Conn.)

(shared Conn.)

DSD to PCM

Conversion

(AES/EBU)

(SDIF2)

(optical)

DSD