EXFO FTB-7000 OTDR for FTB-200 v2 User Manual

Page 229

Advertising
background image

Analyzing Traces with the Bidirectional Analysis Application

OTDR

215

Reanalyzing Traces and Regenerating the Bidirectional Measurement

Reanalyzing Traces and Regenerating the

Bidirectional Measurement

You can analyze the A->B and B->A traces and regenerate the
bidirectional measurement at any time. Reanalyzing a trace will:

³

re-create the events table if it was modified.

³

reset the span start to zero and the span end to end-of-fiber, unless you
have saved them (see Saving the Span-Start and Span-End Information
on page 246).

The table below shows what happens when you start the analysis,
depending on the direction that is currently selected.

Note: In the case of multiwavelength files, the analysis is performed for the

selected wavelength only.

If you prefer to focus your analysis on a specific fiber span, see Modifying
the Alignment of Unidirectional Traces
on page 217.

Current direction

Bidirectional

measurement

A

->

B trace

B

->

A trace

Bidirectional

Regenerated

Reanalyzed

Reanalyzed

A->B

Regenerated

Reanalyzed

Not modified

B->A

Regenerated

Not modified

Reanalyzed

Advertising