Page 30

10. Other functions and settings

10.1 Switch ( SW2 ) function setting

You can select the navigation mode which control by SW2.The navigation of FY-41AP

show in the table,we can just select two modes for SW2 at the same time .

SW2 Mode

Function

Remark

Null

SW-2 Deactivated

SW-2 set to NULL, Flying mode is controlled by
SW-1.

Go Home

Auto Return To Launch

On activation, plane will automatically return to
launch (RTL) point.

Line

Fixed altitude & Heading lock

flight Mode

With no controlling input from the pilot, the
plane will automatically lock current heading &
maintain altitude.

Circle

Auto Circling Mode (ACM)

Automatically fly, circling a fixed point. Centre is
at point of ACM activation.

If you upgrade the firmware to V1.16 or above version ,you need to set the SW2

functions by using

―FYGCS5.11 for FY41AP and Dos‖ software.After FY-41AP connect to

the GCS software successfully , you can select

―Menu->Autopilot Setting->RC Setting‖ to

finish the switch mode setting.

10.2 RC Max Distance Setting

The RC Max Distance Setting will not allow the plane to fly beyond the distance you

have set. Upon reaching this distance, the FY41AP will automatically engage RTL and fly

back to you.