Horizontal flueing options, Vertical flueing options, Cd,e,f a h,i,j – Glow-worm Betacom2 User Manual

Page 7

Advertising
background image

A

H,I,J

D,E,F

A

C

C

D,E,F

D,E,F

H,I,J

C

D,E,F

A

H,I,J

D,E,F

A

H,I,J

C

D,E,F

A

G

H,I,J

Horizontal flue accessories

Top rear and top side horizontal flue options

C

G

A

D,E,F

H,I,J

A

H

I

B

J

D

E

F

G

C

Component

Description

Part Number

Ø60/100

Part Number

Ø80/125

A

Horizontal Telescopic flue

A2043600

0020104551

B

45° Bend (2 off)

2000460485

0020104557

C

90° Bend (1 off)

2000460484

0020104556

D

0.5m Extension (1 off)

2000460481

0020104553

E

1m Extension (1 off)

2000460482

0020104554

F

2m Extension (1 off)

2000460483

0020104555

G

Vertical Flue Adaptor

A2024600

0020104550

H

Deflector Terminal (Black)

0020060582

-

I

Deflector Terminal (White)

0020060583

-

J

Black Terminal

A2043700

-

Horizontal flueing options

Horizontal flue lengths

The horizontal flueing information below applies to all Glow-worm High Efficiency boilers.

Boiler

Ø60/100 Max horizontal Ø80/125 Max horizontal

Compatible with Plume

Management Kit

Betacom

2

24

6m

10m

Yes

1

Betacom

2

28

6m

10m

Yes

1

Notes:

1

The overall maximum flue length

must not be exceeded.

Vertical flue options

A

H

L

I

M

B

J

K

F

G

C,D,E

F

C,D,E

G,M

F

C,D,E

C,D,E

B

B

G,M

F

C,D,E

C,D,E

A

G,M

Vertical flue accessories

Component

Description

Part Number

Ø60/100

Part Number

Ø80/125

A

45° Bend (2 off)

2000460485

0020104557

B

90° Bend (1 off)

2000460484

0020104556

C

0.5m Extension (1 off)

2000460481

0020104553

D

1m Extension (1 off)

2000460482

0020104554

E

2m Extension (1 off)

2000460483

0020104555

F

Vertical Flue Adaptor

A2024600

0020104550

G

Vertical Roof Terminal

2000460480

0020104552

H

Pitched Roof Flashing

2000460479

-

I

Flat Roof Flashing

2000460478

-

J

Sliding Sleeve

2000460487

0020104558

K

Fixing Bracket (5 off)

2000460486

0020104559

L

Telescopic Extension

A2036900

-

M

Ridge Tile Terminal

A2043800

-

Notes:

i

Horizontal sections must have a continuous fall of at least 2.5° (44mm/metre) back to the boiler.

Vertical flueing options

Vertical flue lengths

The vertical flueing information below applies to all Glow-worm High Efficiency boilers.

Boiler

Ø60/100 Max vertical

Ø80/125 Max vertical

Compatible with Plume

Management Kit

Betacom

2

24

6m

10m

Yes

1

Betacom

2

28

6m

10m

Yes

1

Notes:

1

The overall maximum flue length

must not be exceeded.

13

12

Advertising