Technical data, 5 envirosorb 5 – Glow-worm Clearly Heat Pump 5 kW User Manual

Page 11

Advertising
background image

0020111744_00 - 09/10 - Glow-worm

- 9 -

TECHNICAL DATA

TECHNICAL DATA

5 Envirosorb

5

Description

Unit

Envirosorb

5

Min. operational range (in heating)

°C

-7

Max. operational range (in heating)

°C

35

Specifi cations, with radiators

(fl ow : 45°C, return : 40°C, outside dry temperature (wet) 7 (6)°C)

Heating output

kW

4.41

Power input

kW

1.46

Rated electrical current

A

6.34

COP* A7(6) W45-40

3.02

Specifi cations, with fl oor heating

(fl ow : 35°C, return : 30°C, outside dry temperature (wet) : 7 (6)°C)

Heating output

kW

4.70

Power input

kW

1.26

Rated electrical current

A

5.48

COP* A7(6) W35-30

3.73

Refrigerant circuit

Type of refrigerant

R-410A

Quantity of refrigerant

kg

1.8

Type of compressor

Rotary

Type of oil

Polyolester

Type of regulator

Electronic

Fan speed

rpm

180 - 660

Maximum operating pressure (PS) in low
pressure

bar

34

Pa

34 x 10

5

Maximum operating pressure (PS) in high
pressure

bar

43.2

Pa

43.2 x 10

5

Heat pump circuit

Min. supply pressure

bar

1

Pa

1 x 10

5

Max. supply pressure.

bar

3

Pa

3 x 10

5

Minimum static pressure

bar

1

Pa

1 x 10

5

Nominal water fl ow rate in heating mode

l/h

800

Minimum water fl ow rate

l/h

500

Minimum recommended water fl ow

l/h

750

Maximum recommended water fl ow

l/h

850

Minimum outlet temperature setting
(in heating)

°C

25

Maximum outlet temperature setting
(in heating)

°C

55

Heat pump water volume

l

1

Description

Unit

Envirosorb

5

Electrical

Supply voltage/frequency

V/Hz

1/N/PE

230V 50Hz

Fuse (x2)

T2A / 250V

Maximum absorbed power (P max)

kW

1.45

Real power absorbed by the fan and pump
(with heating resistors)

kW

1.48

Real power absorbed by the fan and pump
(without heating resistors)

kW

1.35

Maximum absorbed current (I max)

A

6.70

Real current absorbed by the fan and pump
(with heating resistors)

A

6.43

Real current absorbed by the fan and pump
(without heating resistors)

A

5.88

Starting current (with start-up current limiter)

A

< 20

Index of electrical protection

IPX4

Electrical classifi cation

I

Surge category

II

Pollution rating

2

Description

Unit

Envirosorb

5

Dimensions

Height

mm

935

Width

mm

880

Depth

mm

345

Ø Water circuit connections

"

1

Nett total weight

kg

82.5

Sound power level : overall exterior noise
(according to EN 12102 and EN ISO 9614-1)

dBA

62.6

* Coeffi cient Of Performance (according to EN 14511)
** Energy Effi ciency Ratio (according to EN 14511)

i

Fluorinated greenhouse gases as identifi ed in
the Kyoto protocol, are contained within a fully
sealed system.