14 replacement of parts – Glow-worm Energysaver Combi 80-100 User Manual

Page 33

Advertising
background image

33

221564F

14.11 Gas Valve

Remove the injector pipe as described in section 12.3.

Remove the gas injector as described in section 14.10.

Remove the electrical connections from the gas valve, see
diagram 11.2.

Undo the gas pipe nut from beneath the base panel.

Undo and remove the two securing screws from beneath the
base panel.

Remove the gas valve.

After replacing the gas valve the combustion CO

2

will need to

be checked and adjusted if necessary, see section 12.6.

14.12 Fan

Remove fan as described in section 12.3.

14.13 Burner

Remove fan and burner as described in section 12.3.

14.14 Pump

Refer to section 12.9 and drain the boiler heating circuit.

Undo the pump union nuts.

Unscrew the electrical cover from the pump and remove wiring.

Fit the new pump and refill, vent and pressurise the boiler.

Check for leaks.

14.15 Pressure Relief Valve

Refer to section 12.9 and drain the boiler heating circuit.

Undo the pressure relief valve unions and remove from the
pipework.

Fit new pressure relief valve.

Refill, vent and pressurise the boiler.

Check for leaks.

DOMESTIC HOT
WATER
THERMISTOR

6546

THREE WAY
VALVE HEAD

Diagram 14.1

6530

LOCATION
BUTTON

Diagram 14.3

6568

Diagram 14.2

HEATING FLOW
THERMISTOR

THERMISTOR
RETAINING CLIP

IMPORTANT NOTE:- The thermistor will
fall out of the pocket if the restraining clip
is not fitted as shown.

POCKET

ELECTRICAL
CONNECTION

(2 OFF)

SCREW

SECURING
BRACKET

14 Replacement of Parts

Advertising