10 fault finding – Glow-worm 56-2 Back Boiler User Manual

Page 21

Advertising
background image

21

221781A

10 Fault Finding

Diagram 10.3

THERMOCOUPLE
FAULT FINDING CHART

Diagram 10.4

DIAGNOSIS GRAPH FOR BOILER
THERMOCOUPLE CIRCUIT

1429

Closed Circuit Voltage (millivolts)

Open Circuit Voltage (millivolts)

0

2

4

6

8

10 12 14 16 18 20 22

9

11

13

15

17

19

21

23

25

27

A

B

C

Disconnect appliance thermocouple from the gas valve. Check that all connections are
clean and in good condition. Fit test meter interrupter into the magnet unit. Fit appliance
thermocouple into the test meter interrupter. Check that the flue blockage safety device
sensing filter is clean, if not remove / clean and replace.

NO

YES

Hold down control knob on gas valve. Ignite pilot burner and allow thermocouple to attain
operating temperature. Measure the OPEN CIRCUIT voltage.

Is

voltage
greater

than

15mV?

Faulty thermocouple.
Replace.

Note the open circuit reading then measure the CLOSED CIRCUIT voltage. Note this voltage.
Referring to the diagnosis graph, mark the open circuit voltage on the VERTICAL axis,
and the closed circuit voltage on the HORIZONTAL axis. Note the point where these
two values intersect on the graph.

THERMOCOUPLE
CIRCUIT IS
SATISFACTORY

In

which

area of the

graph is the

intersect

Faulty thermocouple.
Replace.

Faulty magnet unit in gas valve.
Replace .

B

A

C

6131