1 general – Glow-worm 56-2 Back Boiler User Manual

Page 4

Advertising
background image

4

221781A

FULLY PUMPED SYSTEM
(DIAGRAMMATIC)

Diagram 1.4

The COLD FEED PIPE may be connected to the flow
pipe, adjacent to the open vent pipe as shown .
(THERE MUST ALWAYS BE A COLD WATER PATH
TO THE RETURN CONNECTION Of THE BOILER.)

C

L

BOILER

22mm MIN
OPEN VENT

INDIRECT
CYLINDER

MANUAL
AIR VENT

1 metre MIN
27 metres MAX

15mm
COLD
FEED

PUMP

HEATING
CIRCUIT

150mm
MAX

DRAIN COCK

1588

Diagram 1.3

PUMPED HEATING & GRAVITY
DOMESTIC HOT WATER
(DIAGRAMMATIC)

1587

C

L

BOILER

27 metres
MAX

PUMP

HEATING

CIRCUIT

22mm
VENT

Refer to
B.S. 5546

28mm

INDIRECT
CYLINDER

15mm
COLD
FEED

DRAIN COCK

1 General

1.8 Hot Water Cylinder

The back boiler is suitable for open vented systems using an
indirect cylinder (including single feed self priming type). The
indirect cylinder must be fitted to the manufacturer’s
recommendations and the system must conform to the
requirements of the current issue of BS5546 and BS6700.

It is recommended that the indirect cylinder be fitted with some
form of temperature control.

1.9 Frost Protection

If the position of the back boiler is such that it may be vulnerable
to freezing it should be protected as specified in the current
issue of BS5422.

It is also recommended that a frost protection thermostat is
fitted.

1.10 Draining Tap

A draining tap must be provided at the lowest point of the system
which will allow the entire system, the back boiler and hot water
cylinder to be drained.

Draining taps shall be to the current issue of BS2879.

1.11 Safety Valve

A safety valve need not be fitted to an open vented system.

1.12 Back Boiler Location

This back boiler MUST NOT be installed in a private garage or
in a room containing a bath or shower or in a room used or
intended to be used as sleeping accommodation.

1.13 BSI Certification

This appliance is certificated to the current issue of BS6332 Part
1 invoking the current issue of BS5258 Part 8 for safety and
performance. It is, therefore, important that no alteration is
made to it without permission, in writing, from Hepworth Heating
Ltd.

Any alteration that is not approved by Hepworth Heating Ltd.,
could invalidate the BSI Certification of the boiler, warranty and
could infringe the current issue of the Statutory Requirements.

C

L

C

L

3012/A

C

B

405mm

A

* CORNER IN-FILL
(not required to be full
depth of opening)

PREPARED
BOILER
BASE

100mm

Diagram 1.2

FRONT OPENING

A

B

C

Miami 3 BBU

350

405 to 580

560 to 590

Melody 3 BBU

350

405 to 580

560 to 590

Black Ash 3

350

406 to 460

560 to 590

*Brown Ember 3

350

510 to 580

560 to 590

Saxony 3

350

406 to 460

560 to 590