8 servicing, 9 replacement of parts – Glow-worm 45/2 Back Boiler User Manual

Page 17

Advertising
background image

17

221780A

5079

8 Servicing

Diagram 8.9

Diagram 8.8

Diagram 8.6

Diagram 8.7

5201

1620

6048

FLUE
BAFFLE

FLUE COLLECTOR
ASSEMBLY

SECURING
SCREW

STAINLESS STEEL
SECURING SCREWS(2)

GUIDE
CHANNELS

FLUE
BAFFLE

DIVERTER
PLATE

FIRE FRONT
SENSING TUBE

SECURING
SCREW (2)

FLUEWAY
BAFFLES

9.1 Notes on Replacing Parts.

(a) Replacement of parts must be carried out by a competent
person.

(b) Unless stated otherwise all parts are replaced in the reverse
order to that of removal.

(c) After replacing any gas carrying parts always test for gas
soundness using a suitable leak detection fluid. Also carryout
functional check of controls.

(d) Refer to the Gas Fire Front Installation Instructions for
details of the removal of the fire front.

(e) Isolate the electrical supply to the back boiler.

(f) Remove the gas fire front plinth.

(g) Refer to diagram 6.1 to identify the back boiler controls.

Turn the gas valve control knob “A” clockwise to

“Off”

position. Turn the appliance gas service cock anticlockwise to
“Off” position, see diagram 6.2.

9 Replacement of Parts

Diagram 9.1

RETAINING
TABS

IGNITION LEAD
(BLACK END)

PIEZO
UNIT

8033

Advertising